Overall accuracy of the BpTRU--an automated electronic blood pressure device.

نویسندگان

  • Gurdial S Mattu
  • Balraj S Heran
  • James M Wright
چکیده

BACKGROUND The objective of this report is to combine the data from an earlier adult study with the data from a paediatric study in order to determine the overall accuracy of the BpTRU (BPM-100 model) as compared to the recognized standard, auscultatory mercury sphygmomanometer. DESIGN The individual blood pressure points recorded for both adult and paediatric studies were compared directly to its corresponding observer reference measurements from data collected and stored from the two separate studies. There were 255 sets of readings in the adult study and 162 sets from the paediatric study, which were combined to make 417 pairs of blood pressure readings for this study. METHODS The overall observer standard reference mean for the 417 measurements was calculated and the difference between this and the overall mean BPM-100 was calculated with SD and ranges. Measurements within 5, 10 and 15 mmHg agreement were expressed as percentages. RESULTS A total of 121 subjects were included for this study (85 from the adult study and 36 from the paediatric study). From these, 417 paired measurements were recorded. The mean difference between the BpTRU and the reference standard systolic blood pressure (BP) was 0.47+/-5.40 mmHg with 89.2% measurements within 5 mmHg, 96.4% within 10 mmHg and 99.3% within 15 mmHg. The mean difference between the BpTRU and reference diastolic BP was -2.12+/-5.93 mmHg with 81.1% within 5 mmHg, 92.1% within 10 mmHg and 97.6% within 15 mmHg. CONCLUSION The BpTRU has been shown to be an accurate non-invasive blood pressure monitoring device in the general population over a wide range of ages (3-83 years). This combined study meets all requirements of the Association of Advancement of Medical Instrumentation and achieved a grade 'A' in the BHS protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum frequency of office blood pressure measurement using an automated sphygmomanometer.

OBJECTIVE To determine the optimum interval between serial blood pressure measurements using an automated BpTRU sphygmomanometer. METHODS Two groups of 200 patients each had automated office measurements taken using the BpTRU device at either 1-min or 2-min intervals from the start of one reading to the start of the next reading with a 24-h ambulatory blood pressure (ABP) recording being perf...

متن کامل

Optimising the accuracy of blood pressure monitoring in chronic kidney disease: the utility of BpTRU

BACKGROUND Accurate blood pressure monitoring is critical for the management of chronic kidney disease, but changes in management in secondary care clinics may be based on a single blood pressure reading, with a subsequent lack of accuracy. The aim of this study was to evaluate a fully automated sphygmomanometer for optimising the accuracy of blood pressure measurements in the setting of second...

متن کامل

Use of an automated blood pressure recording device, the BpTRU, to reduce the "white coat effect" in routine practice.

BACKGROUND Patients often exhibit higher blood pressure (BP) readings in the doctor's office, a phenomenon known as the white coat effect. This study examines the presence of a physician in the examining room as a possible factor in provoking a white coat effect. METHODS Blood pressure measurements taken by an automated BP recording device, the BpTRU (VSM MedTech Ltd., Vancouver, BC, Canada) ...

متن کامل

Strategies to reduce clinical inertia in hypertensive kidney transplant recipients

BACKGROUND Many kidney transplant recipients have hypertension. Elevated systolic blood pressures are associated with lower patient and kidney allograft survival. METHODS This retrospective analysis examined the prevalence of clinical inertia (failure to initiate or increase therapy) in the treatment of hypertension before and after the introduction of an automated device (BpTRU) in the kidne...

متن کامل

Use of automated office blood pressure measurement to reduce the white coat response.

OBJECTIVE To examine the possibility of reducing the white coat response using an automated sphygmomanometer designed for office use, the BpTRU. Consecutive patients referred from physicians in the community to an ambulatory blood pressure (ABP) monitoring unit in an academic hospital were included in the study. PARTICIPANTS AND METHODS A total of 309 patients referred for diagnosis or manage...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood pressure monitoring

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2004