Methods of electroencephalographic signal analysis for detection of small hidden changes

نویسندگان

  • Hiie Hinrikus
  • Maie Bachmann
  • Jaan Kalda
  • Maksim Sakki
  • Jaanus Lass
  • Ruth Tomson
چکیده

The aim of this study was to select and evaluate methods sensitive to reveal small hidden changes in the electroencephalographic (EEG) signal. Two original methods were considered.Multifractal method of scaling analysis of the EEG signal based on the length distribution of low variability periods (LDLVP) was developed and adopted for EEG analysis. The LDLVP method provides a simple route to detecting the multifractal characteristics of a time-series and yields somewhat better temporal resolution than the traditional multifractal analysis.The method of modulation with further integration of energy of the recorded signal was applied for EEG analysis. This method uses integration of differences in energy of the EEG segments with and without stressor.Microwave exposure was used as an external stressor to cause hidden changes in the EEG. Both methods were evaluated on the same EEG database. Database consists of resting EEG recordings of 15 subjects without and with low-level microwave exposure (450 MHz modulated at 40 Hz, power density 0.16 mW/cm2). The significant differences between recordings with and without exposure were detected by the LDLVP method for 4 subjects (26.7%) and energy integration method for 2 subjects (13.3%).The results show that small changes in time variability or energy of the EEG signals hidden in visual inspection can be detected by the LDLVP and integration of differences methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online Detection of Hydrodynamic Changes in Fluidized Bed using Cross Average Diagonal Line

Online detection of hydrodynamics of gas-solid fluidized bed was characterized using pressure fluctuations by cross recurrence plot (CRP) and cross recurrence quantification analysis (CRQA). Experiments were conducted in a lab scale fluidized bed of various particle sizes 150 μm, 280 μm and 490 μm at different gas velocities. Firstly, pattern changes of cross recurrence plot were discussed and ...

متن کامل

Real-time damage detection of bridges using adaptive time-frequency analysis and ANN

Although traditional signal-based structural health monitoring algorithms have been successfully employed for small structures, their application for large and complex bridges has been challenging due to non-stationary signal characteristics with a high level of noise. In this paper, a promising damage detection algorithm is proposed by incorporation of adaptive signal processing and Artificial...

متن کامل

Intrusion Detection Using Evolutionary Hidden Markov Model

Intrusion detection systems are responsible for diagnosing and detecting any unauthorized use of the system, exploitation or destruction, which is able to prevent cyber-attacks using the network package analysis. one of the major challenges in the use of these tools is lack of educational patterns of attacks on the part of the engine analysis; engine failure that caused the complete training,  ...

متن کامل

Modelling and Simulation of Low-Head Hydro Turbine for Small Signal Stability Analysis in Power System

The hydro turbine dynamics have a considerable influence on the dynamic stability of power system. In the study of dynamic stability, the system is modeled by the linear differential equations (small  signal analysis). Small signal stability of power systems is needed in all conditions and only is dependent on the conditions of power system performance before commotion occurrence. This paper pr...

متن کامل

Kinetics analysis of electrophoretic deposition using small signal and large signal modeling, Case study: Nano-Mullite suspension

Having sufficient and accurate understanding about kinetics of phenomena, could be an important reason for further technological progresses. Finding a white-box mathematical model for weight vs. time curves of Electrophoretic Deposition (EPD) using large and small signal analysis has been studied thoroughly in the present investigation. Weight-Time curves of nano-Mullite suspension have been tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nonlinear Biomedical Physics

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2007