Enhancing the lateral-flow immunoassay for viral detection using an aqueous two-phase micellar system
نویسندگان
چکیده
Availability of a rapid, accurate, and reliable point-of-care (POC) device for detection of infectious agents and pandemic pathogens, such as swine-origin influenza A (H1N1) virus, is crucial for effective patient management and outbreak prevention. Due to its ease of use, rapid processing, and minimal power and laboratory equipment requirements, the lateral-flow (immuno)assay (LFA) has gained much attention in recent years as a possible solution. However, since the sensitivity of LFA has been shown to be inferior to that of the gold standards of pathogen detection, namely cell culture and real-time PCR, LFA remains an ineffective POC assay for preventing pandemic outbreaks. A practical solution for increasing the sensitivity of LFA is to concentrate the target agent in a solution prior to the detection step. In this study, an aqueous two-phase micellar system comprised of the nonionic surfactant Triton X-114 was investigated for concentrating a model virus, namely bacteriophage M13 (M13), prior to LFA. The volume ratio of the two coexisting micellar phases was manipulated to concentrate M13 in the top, micelle-poor phase. The concentration step effectively improved the M13 detection limit of the assay by tenfold from 5 × 10(8) plaque forming units (pfu)/mL to 5 × 10(7) pfu/mL. In the future, the volume ratio can be further manipulated to yield a greater concentration of a target virus and further decrease the detection limits of the LFA.
منابع مشابه
Enhancing the Detection of Urinary Tract Infections Using Two-Phase Aqueous Micellar Systems
Urinary tract infections (UTIs) are a leading cause of health expenditures, in part due to the expensive and lengthy diagnostic method that involves culturing bacteria. A new technique has been developed allowing for faster UTI diagnosis through an electrochemical chip to measure unique ribosomal RNA (rRNA) found in bacteria associated with UTIs. Although this technique has had success, concent...
متن کاملDevelopment of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملThe experimental study of reverse micellar phase in AOT/ Heptane/ (Water or aqueous) as nano template
In this paper electrical conductivity measurements and optical investigations takes place in AOT/ heptane/ (water or aqueous) systems. The water in oil system prepared with adding water in 50% by weight of AOT/ heptane solution. In other systems instead of water, aqueous solutions of 1) zinc acetate and water 2) Potassium Hydroxide and water were used. In each phase, the trend of the electrica...
متن کاملLateral flow immunoassay: Present status, trends and future perspective in diseases detection
This article has no abstract.
متن کاملThe experimental study of reverse micellar phase in AOT/ Heptane/ (Water or aqueous) as nano template
In this paper electrical conductivity measurements and optical investigations takes place in AOT/ heptane/ (water or aqueous) systems. The water in oil system prepared with adding water in 50% by weight of AOT/ heptane solution. In other systems instead of water, aqueous solutions of 1) zinc acetate and water 2) Potassium Hydroxide and water were used. In each phase, the trend of the electrica...
متن کامل