Independent implant parameter effects on SIMOX SOI dislocation formation

نویسنده

  • R. Datta
چکیده

Separation by implanted oxygen (SIMOX) material has proven to provide an extended temperature range (up to 500°C) of operation for partially depleted silicon-on-insulator (SOI) test structures and product circuits in both transportation and communication applications. Such high temperature use is possible due to the built-in dielectric isolation which eliminates the isolation junction and its associated leakage. In order to further improve high temperature performance, material quality must be ever improving. This study examines the independent implant parameter effects of implant energy, implant temperature, and beam current density on the silicon threading dislocation density in standard and thin buried oxide (BOX) SIMOX material. We have found that increased implant energies and a slightly lower beam current will improve the dislocation density by at least an order of magnitude. The kinetics of vacancy formation as it relates to the above parameters are presented. 8 1997 Elsevier Science S.A.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-current Oxygen Ion Implanter for SIMOX

OVERVIEW: SOI (silicon on insulator) technology* has attracted a lot of attention as a promising breakthrough technology for high-speed, low-power LSIs. Research and development aimed at its practical use are now being conducted over a wide range of fields, including circuit design, device, process, and SOI wafer manufacturing. The key to the practical use of SIMOX (separation by implanted oxyg...

متن کامل

A Simple Technique to Measure Generation Lifetime in Partially Depleted SOI MOSFET’s

This brief presents a new, simple method of measuring the generation lifetime in silicon-on-insulator (SOI )MOSFET’s. Lifetime is extracted from the transient characteristics of MOSFET subthreshold current. Using this technique, generation lifetime was mapped across finished Separation by IMplantation of OXygen (SIMOX) wafers and Bonded and Etchedback SOI (BESOI) wafers. BESOI material evaluate...

متن کامل

Measurement of carrier generation lifetime in SOI devices

This paper presents a new, simple method of measuring the generation lifetime in SOI (silicon-on-insulator) MOSFETS. Lifetime is extracted from the transient characteristics of MOSFET subthreshold current. Using this technique, generation lifetime was mapped across ®nished SIMOX (separation by implantated oxygen) wafers, BESOI (bonded and etchedback SOI) wafers, and UNIBOND wafers. BESOI materi...

متن کامل

High-current Ion Implanter for 300-mm SIMOX Wafer Production

OVERVIEW: There is an increased demand for the production of nextgeneration super-high-speed and low-power-consumption CMOS (complementary metal-oxide semiconductor) devices using SOI (silicon on insulator). Major global device manufacturers are actively commercializing this product. In SOI technology, a device is fabricated in a silicon layer (SOI layer) formed on a BOX (buried oxide) film. Al...

متن کامل

Separation by Plasma Implantation of Oxygen (SPIMOX) Operational Phase Space

Separation by plasma implantation of oxygen (SPIMOX) has been suggested as an economic alternative for separation by implantation of oxygen (SIMOX) to form the silicon-oninsulator (SOI) structure. The chief advantage of SPIMOX is the high throughput and low-cost implanter. The operation regime of implantation for SPIMOX, which uses dc plasma immersion ion implantation (PIII) for the oxygen impl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004