High-performance liquid chromatographic method for the determination of ivermectin in plasma.
نویسندگان
چکیده
A simple, sensitive, selective and reproducible method based on reversed-phase chromatography was developed for the determination of ivermectin in human plasma. The internal standard (moxidectin) was separated from ivermectin on a Hypersil Gold C18 column (150 x 4.6 mm, 5 microm particle size), with retention time of 3.7 and 7.0 minutes, respectively. Fluorescence detection was set at an excitation and emission wavelength of 365 and 475 nm, respectively. The mobile phase consisted of acetonitrile, methanol and distilled water (50:45:5, v/v/v), running through the column at a flow rate of 1.5 ml/minute. The chromatographic analysis was operated at 25 degrees C. Sample preparation (100 microl plasma) was done by a single step protein precipitation with acetonitrile, followed by derivatization with 100 microl of N-methylimidazole solution in acetonitrile (1:1, v/v) and 150 microl of trifluoroacetic anhydrous solution in acetonitrile (1:2, v/v). Calibration curve over the concentration range of 20-8000 ng/ml plasma was linear with correlation coefficient better than 0.995. The precision of the method based on within-day repeatability and reproducibility (day-to-day variation) was below 15% (coefficient of variation) Good accuracy was observed for both intra-day and inter-day assays, as indicated by the minimal deviation of mean values found with measured samples from that of the theoretical values (below +15%). Limit of quantification was 0.02 ng using 100 microl sample. The mean recovery for ivermectin and the internal standard was greater than 90%. The method was free from interference from endogenous substances and commonly used drugs. The method appears to be robust and has been applied to the investigation of plasma concentration vs time profile of ivermectin in five healthy Thai volunteers following a single oral dose of 200 microg ivermectin/kg body weight.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Southeast Asian journal of tropical medicine and public health
دوره 37 5 شماره
صفحات -
تاریخ انتشار 2006