Effect of ventilation distribution on aerosol bolus dispersion and recovery.

نویسندگان

  • J S Brown
  • T R Gerrity
  • W D Bennett
چکیده

It has been speculated that convective ventilatory inhomogeneities are an important factor influencing aerosol bolus behavior in the compromised lung. Multiple-breath 133Xe washout (MBWXe) is a commonly accepted test of ventilation distribution. By comparing aerosol bolus parameters to MBWXe in 9 healthy subjects and 14 cystic fibrosis patients with mild-to-moderate airway obstruction, we have attempted to discern the effect of altered ventilation distribution on aerosol bolus dispersion and recovery. Aerosol boluses (150-ml width) were delivered to the volumetric penetrations of 250 and 500 ml. Similar tidal volumes (approximately 1.25 liters) and flow rates (0.4 l/s) were used for aerosol bolus and MBWXe maneuvers. Associations between bolus parameters and ventilation distribution were only observed in the cystic fibrosis patients. We conclude that aerosol bolus dispersion and recovery are both influenced by convective ventilatory inhomogeneities induced by airway obstruction in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Saline aerosol bolus dispersion. I. The effect of acinar airway alteration.

We explored the possibility of using a saline aerosol for bolus dispersion measurements to detect peripheral airway alterations in smokers. Indexes of ventilation inhomogeneity in conductive (S(cond)) and acinar (S(acin)) lung zones, as derived from the multiple-breath N(2) washout (Verbanck S, Schuermans D, Van Muylem A, Noppen M, Paiva M, and Vincken W, J Appl Physiol 83: 1807-1816, 1997), we...

متن کامل

Aerosol Bolus Dispersion and Recovery in a Human and Dog Airway Cast

In recent years methods in lung diagnostics have been developed using the aerosol bolus inhalation technique (Heyder et al., 1988; Anderson et al., 1989; Schulz et al., 1995; Blanchard 1996). A bolus is a small volume of aerosol sandwiched in particle-free air and inhaled into different volumetric regions of the lung. During inhalation and exhalation the original small bolus is dispersed over a...

متن کامل

Aerosol bolus dispersion in healthy subjects.

Aerosol bolus dispersion is a physiological test of lungs, which uses monodisperse submicron particles to measure intrapulmonary convective gas mixing. In this study, aerosol bolus dispersion was measured in healthy subjects in order to assess reference values for possible clinical applications, to assess the reproducibility of these values, and to identify physical and physiological factors in...

متن کامل

Aerosol bolus dispersion and effective airway diameters in mildly asthmatic children.

The contribution of aerosol techniques, the estimation of aerosol bolus dispersion and effective airway dimensions, to the clinical diagnosis of paediatric asthma was studied. In 47 children, aged 11 +/- 2 yrs, with mild asthma (forced expiratory volume in one second (FEV1) 83 +/- 9% of forced vital capacity (FVC)) effective airway diameters were derived from the recovery of inhaled 1 micron se...

متن کامل

Saline aerosol bolus dispersion. II. The effect of conductive airway alteration.

In a companion study (Verbanck S, Schuermans D, Vincken W, and Paiva M, J Appl Physiol 90: 1754-1762, 2001), we investigated whether saline aerosol bolus tests could also be used to detect proximal, as opposed to peripheral, airway alterations. We studied 10 never-smokers before and after histamine challenge, obtaining, for various volumetric lung depths (VLD), saline bolus-derived indexes comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 1998