Simulation of Magnetic Field Topology in a Saddle-Shaped Coil of Nuclear Quadrupole Resonance Spectrometer
نویسنده
چکیده
A topology of high-frequency field intensity in the work area of a saddle-shaped coil for a nuclear qaudrupole resonance spectrometer was studied. With a view to determine magnetic field topology, a computational domain was created which is a model of a saddle-shaped coil physical structure. Finite element method was used to perform numerical simulation in COMSOL Multiphysics software. According to the results of calculations performed and the field maps obtained, the relative volume of coil work area was determined which makes 28.12% of its full volume. For such a volume the recommended size of samples under study is 12× 18× 10mm3.
منابع مشابه
Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملPowder Zeeman NQR Study on 123Sb in Sb(C6H5)3
Powder Zeeman NQR spectra of Sb in Sb(C6H5)3 were studied by means of a computer simulation and an experiment. TheSb nucleus has spin 7/2. There are two non-equivalentSb atoms in the crystal of Sb(C6H5)3, so that there are two series of three transition lines (higher series: 1h, 2h, 3h; lower series: 1l, 2l, 3l). The powder Zeeman spectra for 1h, based on the transition between the levels mI = ...
متن کاملMagnetic Field of RF Coil Measurement by NMR Method
A spectroscopic imaging technique with high spatial resolution was used for the measurement of the static magnetic field homogeneity of RF coils. Measured magnetic fields of optimised and not optimised saddle-shaped coils were compared with the theoretical calculations. Results are in good qualitative agreement between calculated and measured magnetic field distributions. Quantitative disagreem...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملOptimization of Saddle Coils for Magnetic Resonance Imaging
In Nuclear Magnetic Resonance (NMR) experiments, besides the apparatus designed to acquire the NMR signal, it is necessary to generate a radio frequency electromagnetic field using a device capable to transduce electromagnetic power into a transverse magnetic field. We must generate this transverse homogeneous magnetic field inside the region of interest with minimum power consumption. Many con...
متن کامل