STUDY DESIGN The study was based on porcine posterolateral fusion model. OBJECTIVE The study aims to prove that polyelectrolyte complex (PEC) carrier could enhance the efficacy and safety profile of bone morphogenetic protein-2 (BMP-2). SUMMARY OF BACKGROUND DATA BMP-2 was introduced to enhance posterolateral fusion; however, extremely high doses of this molecule were often used which contributed to various complications. This was attributed to the poor modulation capacity of the traditional carrier absorbable collagen sponge (ACS). To reduce the efficacious dose of BMP-2 and its associated complications, heparin-based PEC was introduced. METHODS L3/L4 and L5/L6 two-level posterolateral spinal fusion was performed on six pigs using two doses of BMP-2 with PEC or ACS: (1) PEC with 800 μg BMP-2 (n = 2); (2) PEC with 400 μg BMP-2 (n = 2); (3) ACS with 800 μg BMP-2 (n = 1); (4) ACS with 400 μg of BMP-2 (n = 1). The construct was loaded into a rigid bioabsorbable cage for implantation. Fusion rate and quality were assessed 2 months after operation. RESULTS Manual palpation revealed successful fusion in all groups. Radiological fusion score of PEC groups was, however, higher than that of ACS groups. The newly formed bone in PEC groups appeared to be well integrated into the native bone with no overgrowth into the adjacent structure. On comparison, in ACS groups, large gaps were observed between the newly formed bone and the fusion bed with heterotopic ossification into the psoas muscle. The microarchitecture on the newly formed bone in PEC groups was superior to that in ACS groups, which was demonstrated by higher three-dimensional parameters. CONCLUSION The present study demonstrated that BMP-2 delivered by PEC induced successful posterolateral fusion in porcine model. The efficacy of BMP-2 was improved and bony overgrowth was reduced. The microarchitecture of BMP-2-induced bone tissue was also enhanced by PEC. LEVEL OF EVIDENCE N/A.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved spinal fusion efficacy by long-term delivery of bone morphogenetic protein-2 in a rabbit model

BACKGROUND AND PURPOSE Various new delivery systems for recombinant human bone morphogenetic protein-2 (rhBMP-2) have been introduced to improve its efficacy in osteogenesis. Of these, we have previously developed heparin-conjugated PLGA nanospheres (HCPN) as a long-term delivery system for BMP-2. In vitro studies have shown that the BMP-2 long-term delivery system enhances the level of bone fo...

متن کامل

Sequestration of rhBMP-2 into self-assembled polyelectrolyte complexes promotes anatomic localization of new bone in a porcine model of spinal reconstructive surgery.

Efficient and therapeutically safe delivery of recombinant human bone morphogenetic protein 2 (rhBMP-2) continues to be a central issue in bone tissue engineering. Recent evidence indicates that layer-by-layer self-assembly of polyelectrolyte complexes (PECs) can be used to recreate synthetic matrix environments that would act as tuneable reservoirs for delicate biomolecules and cells. Although...

متن کامل

Ovariectomy-Induced Osteoporosis Does Not Impact Fusion Rates in a Recombinant Human Bone Morphogenetic Protein-2–Dependent Rat Posterolateral Arthrodesis Model

Study Design Randomized, controlled animal study. Objective Recombinant human bone morphogenetic protein-2 (rhBMP-2) is frequently utilized as a bone graft substitute in spinal fusions to overcome the difficult healing environment in patients with osteoporosis. However, the effects of estrogen deficiency and poor bone quality on rhBMP-2 efficacy are unknown. This study sought to determine wheth...

متن کامل

Comparison of posterolateral lumbar fusion rates of Grafton Putty and OP-1 Putty in an athymic rat model.

STUDY DESIGN Posterolateral lumbar spine fusions in athymic rats. OBJECTIVES To compare spine fusion rates of two different osteoinductive products. SUMMARY OF BACKGROUND DATA Many osteoinductive bone graft alternatives are available. Grafton (a demineralized bone matrix [DBM]) and Osteogenic Protein-1 (OP-1, an individual recombinant bone morphogenetic protein) are two such alternatives. T...

متن کامل

Freeze-dried k-carrageenan/chitosan polyelectrolyte complex-based insert: a novel intranasal delivery system for sumatriptan succinate

Intranasal route, ensuring suitable bioavailability of medicines under circumvention of the gastrointestinal degradation and hepatic first-pass elimination, has been a popular choice for drug delivery. Among nasal dosage forms, mucoadhesive solid inserts have been shown to resist mucociliary clearance and provide a prolonged nasal residence time. Hence, the purpose of this study was the prepara...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 41 15  شماره 

صفحات  -

تاریخ انتشار 2016