Effects of fiberoptic bronchoscopy during mechanical ventilation in a lung model.
نویسندگان
چکیده
STUDY OBJECTIVES To evaluate the effects of fiberoptic bronchoscopy (FOB) on delivered volumes and pressures during mechanical ventilation, utilizing a lung model. DESIGN Bench study. SETTING Laboratory. MATERIALS AND METHODS Using varying-sized endotracheal tubes (ETTs), we ventilated a lung model at two levels of compliance utilizing different modes and parameters of ventilation. After establishing baseline measurements, the bronchoscope was inserted and measurements repeated. MEASUREMENTS AND RESULTS During controlled mechanical ventilation (CMV) with a preset high-pressure limit (HPL), tidal volumes (VTs) were reduced from 700 mL to 0 to 500 mL following insertion of the bronchoscope. Increasing the HPL to 120 cm H(2)O resulted in a VT of 40 to 680 mL. Changing from square to decelerating flow waveform resulted in no consistent difference in VT. Auto-positive end-expiratory pressure (auto-PEEP) of 0 to 41 cm H(2)O was present under most conditions. Higher rates and lower peak inspiratory flows were associated with higher levels of auto-PEEP. In the pressure-control (PC) mode, using a preset inspiratory pressure level (IP), VT was reduced from 700 mL to 40 to 280 mL following insertion of the bronchoscope. Maximum IP (100 cm H(2)O) increased VT to 260 to 700 mL. Auto-PEEP was less in the PC mode. CONCLUSIONS Extreme care must be taken when bronchoscopy is performed on a patient receiving mechanical ventilation. Extremely low VT and significant auto-PEEP may develop unless flow, respiratory rate, mode, and ETT size are carefully selected. The PC mode delivered more volume than did the CMV mode. When performing FOB during mechanical ventilation, the inside diameter of the ETT should be > or = 2.0-mm larger than the outside diameter of the bronchoscope to maintain volume delivery and minimize the development of auto-PEEP.
منابع مشابه
Flexible bronchoscopy during mechanical ventilation in the prone position to treat acute lung injury.
In patients with severe acute lung injury (ALI) or acute respiratory distress syndrome (ARDS) the prone position has been shown to improve survival of patients who are severely hypoxemic with an arterial oxygen tension to inspiratory oxygen fraction ratio (PaO(2)/FiO(2))<100. In those patients tracheobronchial toilette is crucial in preventing or treating airways obstructed by secretions and de...
متن کاملA novel non-invasive ventilation mask to prevent and manage respiratory failure during fiberoptic bronchoscopy, gastroscopy and transesophageal echocardiography
Fiberoptic bronchoscopy (for difficult intubation, bronchoalveolar lavage or biopsies), gastric endoscopies and transesophageal echocardiography (for transfemoral aortic valve replacement, MitraClip or left atrial appendage closure), are widespread diagnostic and therapeutic procedures. Non-invasive ventilation during upper endoscopies can be used to prevent or treat acute respiratory failure e...
متن کاملDouble lumen endotracheal tube for percutaneous tracheostomy?
BACKGROUND Percutaneous dilational tracheostomy is normally a bronchoscope-guided procedure. The insertion of a bronchoscope into an endotracheal tube (ETT) affects resistance, flow, and alveolar pressure. To improve airway management and ventilation during percutaneous tracheostomy, we developed a double lumen endotracheal tube (DLET). The aim of this in vitro study was to compare the linear c...
متن کاملSevere excessive dynamic airway collapse in a patient with primary Sjögren's syndrome.
Airway and cystic lung diseases can be observed in patients with Sjögren's syndrome. We report a case of such a patient suffering from respiratory failure due to recurrent episodes of right pneumothorax, requiring invasive mechanical ventilation. Despite thoracic drainage and adequate pneumothorax management, the patient could not be weaned from the ventilator. Fiberoptic bronchoscopy revealed ...
متن کاملDouble Lumen Endotracheal Tube for Percutaneous Tracheostomy
BACKGROUND: Percutaneous dilational tracheostomy is normally a bronchoscope-guided procedure. The insertion of a bronchoscope into an endotracheal tube (ETT) affects resistance, flow, and alveolar pressure. To improve airway management and ventilation during percutaneous tracheostomy, we developed a double lumen endotracheal tube (DLET). The aim of this in vitro study was to compare the linear ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 118 3 شماره
صفحات -
تاریخ انتشار 2000