Microheaters based on ultrasonic actuation of piezoceramic elements
نویسندگان
چکیده
This paper describes the use of micromachined lead zirconate titanate (PZT) piezoceramic elements for heat generation by ultrasonic energy dissipated within the elements and surrounding media. Simulations based on three-dimensional finite-element models suggest that circular disk-shaped elements provide superior steady-state temperature rise for a given cross-sectional area, volume of the PZT element and drive voltage. Experimental validation is performed using PZT-5A heaters of 3.2 mm diameter and 0.191 mm thickness. Single-element heaters and dual-element stacks are evaluated. Although the steady-state temperature generated by these heaters reaches the maximum value at the frequency of maximum electromechanical conductance, the heating effectiveness is maximized at the frequency of maximum electromechanical impedance. Stacked PZT heaters provide 3.5 times the temperature rise and 3 times greater heating effectiveness than single elements. Furthermore, the heaters attain the maximum heating effectiveness when bonded to highly damping and non-conducting substrates. A maximum temperature of 120 ◦C is achieved at 160 mW input power. Experiments are performed using porcine tissue samples to show the feasibility of using PZT heaters in tissue cauterization. A PZT heater probe brands a porcine tissue in 2–3 s with 10 VRMS drive voltage. The interface temperature is ≈150 ◦C. (Some figures in this article are in colour only in the electronic version)
منابع مشابه
Piezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter
Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...
متن کاملA biopsy tool with integrated piezoceramic elements for needle tract cauterization and cauterization monitoring.
This paper reports the feasibility of biopsy needle tract cauterization and cauterization monitoring using an embedded array of piezoceramic microheaters. Circular heaters of lead zirconate titanate (PZT-5A), with 200 μm diameter and 70-80 μm thickness, are fabricated using a batch mode micro ultrasonic machining process. These are then assembled into cavities in the walls of 20-gauge stainless...
متن کاملImproved Ultrasonic Piezoceramic Sandwich Transducer
This paper presents an improved ultrasonic piezoceramic sandwich transducer, utilised for ultrasonic field in narrow lift stations, wet well, flumes and filter beds. The piezoceramic sandwich transducer powered by a signal generator and it is suitable to generate ultrasound with two piezoceramics and the exponential horn at 35 kHz resonance frequency. From the experiments it can be proved that ...
متن کاملFinite element simulation of the vibration modes for the piezoceramic plates used in ultrasonic motors
The article presents resarches for designing and manufacturing of the ultrasonic motors that uses piezoceramic materials. There are presented specific vibrations modes for the studied piezoceramic plates, vibrations that are used to excite the motor activated element (mobile element). Using the finite element method it is really posssible to predict the usefull vibrations that can makes easier ...
متن کاملEnhanced torsional actuation and stress coupling in Mn-modified 0.93(Na0.5Bi0.5TiO3)-0.07BaTiO3 lead-free piezoceramic system
This paper is concerned with the development of a piezoelectric d15 shear-induced torsion actuator made of a lead-free piezoceramic material exhibiting giant piezoelectric shear stress coefficient (e15) and piezoelectric transverse shear actuation force comparable to that of lead-based shear-mode piezoceramics. The Mn-modified 0.93(Na0.5Bi0.5TiO3)-0.07BaTiO3 (NBT-BT-Mn) composition exhibited ex...
متن کامل