Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.
نویسندگان
چکیده
AIM To evaluate the accuracy of axial length (AL) measurements obtained from immersion B-scan ultrasonography (immersion B-scan) for intraocular lens (IOL) power calculation in patients with high myopia and cataracts. METHODS Immersion B-scan, contact A-scan ultrasonography (contact A-scan), and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation. Patients were divided into two groups according to the AL: one containing patients with 22 mm≤AL<26 mm(group A) and the other containing patients with AL≥26 mm (group B). The mean error (ME) was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error. RESULTS In group A, ALs measured by immersion B-scan (23.48±1.15) didn't differ significantly from those measured by the IOLMaster (23.52±1.17) or from those by contact A-scan (23.38±1.20). In the same group, the standard deviation (SD) of the mean error (ME) of immersion B-scan (-0.090±0.397 D) didn't differ significantly from those of IOLMaster (-0.095±0.411 D) and contact A-scan (-0.099±0.425 D). In group B, ALs measured by immersion B-scan (27.97±2.21 mm) didn't differ significantly from those of the IOLMaster (27.86±2.18 mm), but longer than those measured by Contact A-scan (27.75±2.23 mm, P=0.009). In the same group, the standard deviation (SD) of the mean error (ME) of immersion B-scan (-0.635±0.157 D) didn't differ significantly from those of the IOLMaster (-0.679±0.359 D), but differed significantly from those of contact A-scan (-0.953±1.713 D, P=0.028). CONCLUSION Immersion B-scan exhibits measurement accuracy comparable to that of the IOLMaster, and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can't be used, and it is more accurate than the contact A-scan.
منابع مشابه
Immersion A-scan compared with partial coherence interferometry: outcomes analysis.
PURPOSE To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING Oregon Eye Institute, Eugene, Oregon, USA. METHODS Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound ...
متن کاملThe Analysis of Refraction and Accommodation of Extreme Myopia with Cataract after Phacoemulsification and IOL Implantation
Background: To assess the refractive status of cataract patients with extreme myopia and to measure their accommodative capability after monofocal IOL implantation. Design: Prospective non-randomized study conducted at Tianjin Medical University Eye Centre. Participants: 18 patients with 34 extreme myopic eyes (≥-10 Diopter, ≥27mm axial length), and 14 patients with 27 non-myopic eyes that had ...
متن کاملEfficacy and Safety of Cataract Extraction with Negative Power Intraocular Lens Implantation§
PURPOSE To evaluate the visual and refractive outcomes, lens power calculation accuracy, and safety of negative power intraocular lenses (IOLs) implanted in highly myopic eyes at the time of cataract surgery. DESIGN Interventional case series. METHODS Sixteen consecutive highly myopic eyes implanted with IOLs from -1 D to -6 D were identified. IOL power; preoperative and postoperative best-...
متن کاملComparison of axial length of the eye in patients with diabetic retinopathy and non diabetics
Introduction: To compare the axial length of globe in patients with diabetic retinopathy with that in normal population and to evaluate its role in the progression of diabetic retinopathy. Methods: 150 patients with diabetic retinopathy in both eyes were compared with 150 age and sex matched non diabetic patients, referred to Motahari retina clinic of Shiraz, during fall 2000. The axial length...
متن کاملPartial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes
PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2014