Biomechanical comparison of axial load between cannulated locking screws and noncannulated cortical locking screws.

نویسندگان

  • Shan-Wei Yang
  • Shyh Ming Kuo
  • Shwu Jen Chang
  • Tian-Shiang Su
  • Hsiang-Ho Chen
  • Jenn-Huei Renn
  • Ting-Sheng Lin
چکیده

The goal of this study was to compare the biomechanical stability of cannulated locking screws and noncannulated cortical locking screws in a periarticular locking plate. Twelve fresh-frozen porcine tibias with a 1-cm gap created distal to the tibial plateau were used to simulate an unstable proximal tibial fracture. All specimens were fixed with a periarticular proximal lateral tibial locking plate and divided into 2 groups based on whether the proximal metaphyseal screw holes of the plate were inserted with either cannulated locking screws or noncannulated cortical locking screws. An axial compressive load was applied to cause failure in each specimen using a materials testing instrument. The axial stiffness and maximum failure strength in axial loading were recorded. Axial stiffness of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P=.006). Axial failure strength of the constructs using noncannulated cortical locking screw was significantly higher than that of the constructs using cannulated locking screws (P=.002). The failure mode observed in all specimens was a permanent screw-bending deformity over the head-shaft junction of proximal metaphyseal screws, irrespective of whether they were cannulated or noncannulated cortical locking screws. Fixation with noncannulated cortical locking screws offered more stability than cannulated locking screws with regard to axial stiffness and failure strength in a porcine model with unstable proximal tibial fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Fracture fixation with two locking screws versus three non-locking screws

OBJECTIVES We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone. METHODS Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two...

متن کامل

Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length

OBJECTIVES To evaluate the postoperative stability of osteoporotic distal radius fractures fixed with distal locking screws with different length. METHODS A comminuted extra-articular dorsally unstable distal radius fracture, treated with volar locking plate system, was created. The 18 specimens were randomized into 3 groups based on distal locked screws with different length: Group A had uni...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Humeral Fracture Fixation Techniques: a Fea Comparison of Locking and Compression Techniques with Cadaveric Pullout Comparison of Cortical Compression and Internal Locking Screws

Title of Document: HUMERAL FRACTURE FIXATION TECHNIQUES: A FEA COMPARISON OF LOCKING AND COMPRESSION TECHNIQUES WITH CADAVERIC PULLOUT COMPARISON OF CORTICAL COMPRESSION AND INTERNAL LOCKING SCREWS. Aaron Johnson, MS Mechanical Engineering, 2007 Directed By: Professor, Donald Barker, Mechanical Engineering Locking and non-locking humeral repair techniques provide different mechanical constructs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2013