Combined in vivo optical and µCT imaging to monitor infection, inflammation, and bone anatomy in an orthopaedic implant infection in mice.
نویسندگان
چکیده
Multimodality imaging has emerged as a common technological approach used in both preclinical and clinical research. Advanced techniques that combine in vivo optical and μCT imaging allow the visualization of biological phenomena in an anatomical context. These imaging modalities may be especially useful to study conditions that impact bone. In particular, orthopaedic implant infections are an important problem in clinical orthopaedic surgery. These infections are difficult to treat because bacterial biofilms form on the foreign surgically implanted materials, leading to persistent inflammation, osteomyelitis and eventual osteolysis of the bone surrounding the implant, which ultimately results in implant loosening and failure. Here, a mouse model of an infected orthopaedic prosthetic implant was used that involved the surgical placement of a Kirschner-wire implant into an intramedullary canal in the femur in such a way that the end of the implant extended into the knee joint. In this model, LysEGFP mice, a mouse strain that has EGFP-fluorescent neutrophils, were employed in conjunction with a bioluminescent Staphylococcus aureus strain, which naturally emits light. The bacteria were inoculated into the knee joints of the mice prior to closing the surgical site. In vivo bioluminescent and fluorescent imaging was used to quantify the bacterial burden and neutrophil inflammatory response, respectively. In addition, μCT imaging was performed on the same mice so that the 3D location of the bioluminescent and fluorescent optical signals could be co-registered with the anatomical μCT images. To quantify the changes in the bone over time, the outer bone volume of the distal femurs were measured at specific time points using a semi-automated contour based segmentation process. Taken together, the combination of in vivo bioluminescent/fluorescent imaging with μCT imaging may be especially useful for the noninvasive monitoring of the infection, inflammatory response and anatomical changes in bone over time.
منابع مشابه
Monitoring Bacterial Burden, Inflammation and Bone Damage Longitudinally Using Optical and μCT Imaging in an Orthopaedic Implant Infection in Mice
BACKGROUND Recent advances in non-invasive optical, radiographic and μCT imaging provide an opportunity to monitor biological processes longitudinally in an anatomical context. One particularly relevant application for combining these modalities is to study orthopaedic implant infections. These infections are characterized by the formation of persistent bacterial biofilms on the implanted mater...
متن کاملTechnetium-99m tricarbonyl labeled a broad-spectrum quinolone as a specific imaging agent in infection diseases
Nuclear medicine imaging has been used to localize infection sites and efforts have been continued to develop modified infection specific radiopharmaceuticals. In this study gemifloxacin as a broad-spectrum quinolone has been labeled with [99mTc (CO)3 (H2O)3]+ core in order to evaluate its feasibility as an infection imaging agent for in vivo use. The stability of radioconjugate was checked in ...
متن کاملTechnetium-99m tricarbonyl labeled a broad-spectrum quinolone as a specific imaging agent in infection diseases
Nuclear medicine imaging has been used to localize infection sites and efforts have been continued to develop modified infection specific radiopharmaceuticals. In this study gemifloxacin as a broad-spectrum quinolone has been labeled with [99mTc (CO)3 (H2O)3]+ core in order to evaluate its feasibility as an infection imaging agent for in vivo use. The stability of radioconjugate was checked in ...
متن کاملClinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy
Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...
متن کاملDiabetic Mouse Model of Orthopaedic Implant-Related Staphylococcus Aureus Infection
BACKGROUND Periprosthetic bacterial infections represent one of the most challenging orthopaedic complications that often require implant removal and surgical debridement and carry high social and economical costs. Diabetes is one of the most relevant risk factors of implant-related infection and its clinical occurrence is growing worldwide. The aim of the present study was to test a model of i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of visualized experiments : JoVE
دوره 92 شماره
صفحات -
تاریخ انتشار 2014