Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial.

نویسندگان

  • Byunghoon Chung
  • Hun Lee
  • Moonjung Choi
  • Kyoung Yul Seo
  • Eung Kweon Kim
  • Tae-Im Kim
چکیده

AIM To compare characteristics of preloaded and non-preloaded intraocular lens (IOL) delivery systems during IOL delivery procedures. METHODS Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including iSert250 NC60 (NC60), EnVista MX60 (MX60), AcrySof IQ SN60WF (SN60WF), TECNIS ZCB00 (ZCB00), and TECNIS PCB00 (PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via non-preloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device (OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodium-stained OVD. RESULTS The average time for IOL implantation was 22.0s for NC60, 43.2s for MX60, 32.3s for SN60WF, 41.4s for ZCB00, and 14.6s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery

PURPOSE The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. METHODS Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion dat...

متن کامل

Optic Fracture of the Preloaded Intraocular Lens during Insertion

Dear Editor, Intraocular lens (IOL) fracture is a relatively rare complication of cataract surgery during IOL implantation [1]. Foldable IOLs specifically are often fractured by either forceps or injector systems during IOL loading [2,3]. To improve the efficacy and safety of cataract surgery, many preloaded IOLs have been developed and are widely used. Here, we report the first optic fracture ...

متن کامل

A Case of Delayed-Onset Propionibacterium acnes Endophthalmitis after Cataract Surgery with Implantation of a Preloaded Intraocular Lens

PURPOSE To report a case of delayed-onset endophthalmitis after implantation of a preloaded intraocular lens (IOL) and examine the surgically removed IOL by scanning electron microscopy (SEM). CASE A 77-year-old female underwent uneventful phacoemulsification and aspiration with preloaded silicone IOL implantation. Since intraocular inflammation unexpectedly worsened 1 month after the surgery...

متن کامل

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

Effect of Co-Implantation of a Capsular Tension Ring on Clinical Outcomes after Cataract Surgery with Monofocal Intraocular Lens Implantation

PURPOSE The objective was to evaluate the effect of co-implantation of a preloaded capsular tension ring (CTR) and aberration-free monofocal intraocular lens (IOL) on clinical outcomes and visual quality after cataract surgery. MATERIALS AND METHODS Patients who underwent cataract surgery were randomized into two groups that were implanted with a CTR and IOL (group 1, 26 eyes) or an IOL only ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of ophthalmology

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2018