A Three Phase Four Wire Shunt Active Power Filter Control Algorithm under Unbalanced and Distorted Supply Voltage
نویسنده
چکیده
In this paper a control algorithm is validated with simulation studies in MAT environment and experimental studies are performed in to validate the proposed control algorithm. The projected algorithm to compensate the nonlinear and loads in three phase four wire distribution system using shunt active power filter. In this algorithm a positive sequence extraction of the supply voltage and the theory of instantaneous symmetrical component. To exemplify the concept, a three phase four wire with unbalance and non linear load is considered for compensation and detailed simulation and experimental studies are presented.
منابع مشابه
Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملA New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions
To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion ...
متن کاملA New Control Algorithm of Shunt Active Power Filter under Distorted Grid Voltage and Unbalanced Supply Conditions
To achieve maximum possible power factor and by keeping total harmonic distortion (THD) within the acceptable limit. A new control algorithm of shunt active power filter under distorted grid voltage and unbalanced supply conditions is proposed. A new control algorithm renders the optimal compromise between harmonic free (HF) and unity power factor (UPF) by keeping the total harmonic distortion ...
متن کاملAnalysis And Simulation Of Shunt Active Power Filter Under Unbalanced And Distorted Load Conditions
Abstract— The active power filters eliminates the harmonic distortion caused by non-linear loads and improves the filtering efficiency performance when compared with the passive filters. This paper inspects about the analysis and simulation of a three phase four wire shunt active power f ilter under unbalanced and distorted load conditions. Current harmonic compensation is achieved by the imple...
متن کامل