Development of a Biofidelic 'Legform' Impact Test Device

نویسنده

  • Peter Schuster
چکیده

Current EuroNCAP test specifications attempt to predict pedestrian lower limb injury in a lateral impact with a rigid legform test device developed by the UK's TRL (Transportation Research Lab). Research shows that the measurements taken from this device (knee bending angle, knee shear, and upper tibia acceleration) do not necessarily correspond to accurate injury prediction. Recent research suggests that the primary improvement to the current test device would be a flexible legform, or one that has more biofidelity (i.e., simulates actual human lower limb response). The work presented in this paper first reviews current legforms developed for pedestrian impact testing, including the TRL impactor used in EuroNCAP tests, Honda's POLAR II pedestrian dummy, and JAMNJARI's FLEX-PLI legform impactor. Component level testing shows the FLEX-PLI performance to be close to the human lower limb response corridors. However, there are still areas of potential improvement with this design. To address these areas, this research includes the phase 1 development of a new legform impactor incorporating adjustable ligament pre-load, direct ligament strain measurements, adjustability in knee flexion to account for the gait cycle, tuned composite bone cores that match the force-deflection curves of PMHS testing, and a condyle load plate that measures knee joint compressive forces. Development techniques include solid modeling, computer-aided manufacturing, composite design and analysis, sensor specifications, and data acquisition. In so doing, the injury specifications set by the EEVC will be modified to account for the more accurate injury assessment of the improved device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Konosu 1 DEVELOPMENT OF A BIOFIDELIC PEDESTRIAN LEGFORM IMPACTOR - INTRODUCTION OF JAMA-JARI LEGFORM IMPACTOR Ver. 2002 -

The Japan Automobile Manufacturers Association, Inc., (JAMA) and the Japan Automobile Research Institute (JARI) are collaborating to develop a biofidelic pedestrian legform impactor because the current major pedestrian legform impactor, the Transport Research Laboratory (TRL) legform impactor, lacks biofidelity. JAMA and JARI have been developing a biofidelic legform impactor since 2000. This r...

متن کامل

Biofidelity of Test Devices and Validity of Injury Criteria for Evaluating Knee Injuries to Pedestrians

In the current test procedure proposed by the European Enhanced Vehicle-safety Committee (EEVC) /WG17 for evaluating leg injuries to pedestrians, a legform impactor with a rigid bony structure is used. The risk of damages to knee ligaments is evaluated with the shearing displacement and the bending angle at the knee joint. A recent study has focused on evaluating biofidelity of the legform. How...

متن کامل

Validation of Pedestrian Lower Limb Injury Assessment using Subsystem Impactors

Although the biofidelity improvements of the pedestrian legform called the Flexible Pedestrian Legform Impactor (FlexPLI) relative to the conventional legform (EEVC legform) have been shown in past studies, their effects on the evaluation of safety performance of vehicles have not been clarified in a quantitative and comprehensive manner. The goal of this study was to clarify the diffe...

متن کامل

The Study on Developing Active Hood Lift System for Decreasing Pedestrian Head Injury

Active hood lift system has been developed to get more spaces for decreasing the head injury during pedestrian impact. This system is composed of detecting sensor, ECU where the algorithm is embedded and the pyro-type actuators which raise the hood. By this system, the rear part of the hood is raised up to approximately 120mm. The test results of system operation are introduced for each three t...

متن کامل

Evaluation of the BioRID P3 and the Hybrid III in pendulum impacts to the back--a comparison to human subject test data.

The BioRID P3 (Biofidelic Rear Impact Dummy) and the Hybrid III were evaluated in pendulum impacts to the back and compared to data from previous cadaver tests. The test setup impacting seated cadavers was reproduced with a pendulum impacting seated dummies at the level of T6 (6th thoracic vertebra). The pendulum mass was 23 kg and the impact velocity 4.6 m/s. The results showed that the BioRID...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012