Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

نویسندگان

  • M T Kelly
  • F J Roberts
  • D Henry
  • I Geere
  • J A Smith
چکیده

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 isolates that were judged to be clinically significant by chart review were recovered during the study. The BACTEC resin system detected 510 (85%) and the Isolator system detected 435 (72%) of the clinically significant isolates (P less than 0.001). Of 45 polymicrobial blood cultures, the BACTEC system detected 32 (71%) and the Isolator system detected 21 (47%) (P less than 0.05). Of 253 gram-negative bacilli isolated during the study, 30% were detected only in the BACTEC system and 16% were detected only in the Isolator system (P less than 0.001), and of 56 nonfermentative or fastidious gram-negative bacilli detected, 46% were recovered only in the BACTEC system, while 14% were detected only in the Isolator system (P less than 0.001). Of 86 streptococci isolated during the study, 30% were detected only in the BACTEC system, and 4% were detected only in the Isolator system (P less than 0.001). Recoveries of anaerobic bacteria, staphylococci, and yeasts were equivalent in the two systems. Organisms judged to be contaminants were detected in approximately 1% of the cultures in each system. The results suggest that use of resin media renders the BACTEC nonradiometric system equivalent or superior to the Isolator system for detection of clinically significant organisms in blood cultures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical comparison of lysis-centrifugation and radiometric resin systems for blood culture.

The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) and the BACTEC 16B-17D radiometric resin system (Johnston Laboratories, Inc., Towson, Md.) both remove antimicrobial agents from the blood for culture. We compared these two systems for recovery of aerobic bacteria, facultatively anaerobic bacteria, and yeasts. A total of 5,000 blo...

متن کامل

Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections.

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles w...

متن کامل

Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...

متن کامل

Comparison of methods for isolating Mycobacterium avium-intracellulare from blood of patients with AIDS.

A variety of blood culture media were compared to determine the optimal method for the isolation of Mycobacterium avium-intracellulare (MAI) from the blood of patients with AIDS. Simulated laboratory blood cultures and clinical blood cultures were tested. Glucose broth, Bactec aerobic medium, Kirschner's medium, and Bactec Middlebrook medium supported the growth of MAI. The Isolator system, a l...

متن کامل

Clinical comparison of Sentinel, a novel blood culture system, with radiometric Bactec 460 and Isolator 10 in the detection of streptococcal and anaerobic bacteraemias.

AIMS To compare the performance of the Sentinel blood culture system with two other systems for the recovery of streptococci and anaerobes. METHODS Blood cultures were taken from 55 patients one to two minutes after dental extraction. The samples were tested by the radiometric Bactec 460; the Isolator 10, which works by lysis centrifugation; and Sentinel, a fully automated system, which detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 1990