Reference frames in early motion detection.

نویسندگان

  • Camille Morvan
  • Mark Wexler
چکیده

To perceive the real motion of objects in the world while moving the eyes, retinal motion signals must be compensated by information about eye movements. Here we study when this compensation takes place in the course of visual processing, and whether uncompensated motion signals are ever available. We used a paradigm based on asymmetry in motion detection: Fast-moving objects are found easier among slow-moving distractors than are slow objects among fast distractors. By coupling object motion to eye motion, we created stimuli that moved fast on the retina but slowly in an eye-independent reference frame, or vice versa. In the 100 ms after stimulus onset, motion detection is dominated by retinal motion, uncompensated for eye movements. As early as 130 ms, compensated signals become available: objects that move slowly on the retina but fast in an eye-independent frame are detected as easily as those that move fast on the retina.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the frequency content of earthquake excitation on damage detection in steel frames

In this study, the effect of earthquake frequency content and noise effects on damage detection has been investigated. For this purpose, the damage was defined as nonlinear behavior of beams and columns, and several ground motion records were scaled so that some elements yield under the applied excitation. Then the acceleration response data of each floor obtained using the nonlinear dynamic an...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

Apparent motion and reference frames

This article presents a selective overview of motion perception starting with its early philosophical underpinnings. Its role in Gestalt psychology is highlighted including the discovery of the relativity of motion perception and form-motion interactions. The use of reference frames in the computation of motion is illustrated with examples, leading to its current implications on non-retinotopic...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vision

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2005