Simulation of Power Transformer Protection Using Microcontroller Relay
نویسندگان
چکیده
Power transformers are key components for electrical energy transfer in a Power system. In order to protect the transformers from these faults different protective methods are adopted. Some of them are differential protection, over excitation Protection, etc. In this Paper Over Voltage protection is established for the protection of the transformer. Microcontroller is used for the Power Transformer Protection as a relay. It will sense the fault Due to over voltage of about +5% and send trip signal to the relay driver circuit and the power transformer will automatically get isolated from the system. The Simulation circuit is designed in Proteus Software and analyzed successfully. The Programming is also done accordingly.
منابع مشابه
Fault and Theft Recognition Using Toro Dial Sensor in Programmable Current Relay for Feeder Security
Feeder protection is important in transmission and distribution side because if any fault occurs in any feeder or transformer, man power is needed to identify the problem and it will take more time. In the existing system, directional overcurrent elements with load further secured by a load encroachment function can be used to provide necessary security and sensitivity for faults on remote poin...
متن کاملDesigning of a New Transformer Ground Differential Relay Based on Probabilistic Neural Network
Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...
متن کاملA New Restricted Earth Fault Relay Based on Artificial Intelligence
The restricted earth fault (REF) relay is a type of differential protection which is used for detection of internal ground faults of power transformers. But, during external faults and transformer energization conditions, the probability of current transformer (CT) saturation increases. Thus, the spurious differential current due to CT saturation, can lead to REF relay maloperation. In this pap...
متن کاملDesign of Online Ups System with Over Voltage , Under Voltage and Phase Out Protection
Uninterruptible power supplies (UPS) play an important role in interfacing critical loads such as computers, communication systems, medical/life support system and industrial controls to the utility power grid. They are designed to provide clean and continuous power to the load under essentially any normal or abnormal utility power condition. Among the various UPS topologies such as online UPS,...
متن کاملModeling and Simulation of Modern Digital Differential Protection Scheme of Power Transformer based on FIS
In this paper, a differential protection schemes using fuzzy inference system (FIS) for power transformer protection is presented. First we review the concept of differential protection, and illustrate the magnetizing inrush current as they belong to the causes of the protection maloperation. Then relay logic and the algorithm that uses Discreet Fourier transformer for extraction of fundamental...
متن کامل