Phase Current Differential Protection for Transformers in Wye-delta Mode
نویسندگان
چکیده
For the current transformers (CTs) on the delta side measure the line current instead of the phase current, line current differential protection is adopted in transformers connected in wye-delta mode currently. However, the symmetry feature of inrush current in line current differential protection may invalidate the inrush current restrained criterion. A calculating method of current through delta windings according the measured current from CT is proposed in this paper. Using this calculated current, phase current differential protection can be realized. Based on the method an adaptive second harmonic restrained scheme for magnetizing inrush current is presented. The scheme not only adaptively adjusts the secondary harmonic ratio of restrained current but also guarantees the fast action when transformers with internal faults are no-load energized. Consequently the performance of transformer differential protection is greatly improved. Simulation results in Matlab/Simulink validate the proposed method.
منابع مشابه
Power Flow Analysis of Three Phase Unbalanced Radial Distribution System
This paper provides a new approach for power flow and modeling analysis of three phase unbalanced radial distribution systems (URDS) using the simple forward/backward sweep-based algorithm. A three phase load flow solution is proposed considering voltage regulator and transformer with detailed load modeling, for the transformer modeling symmetrical components theory is used and zero sequence-vo...
متن کاملModeling and Simulation of Hybrid Electric Vehicle Power Systems
Using a top-down design methodology, two levels of hybrid electric vehicle power system are presented in the paper. At the highest abstraction level, a behavior modeling method is used to develop models for 3-phase AC/DC converter and brushless DC motor controller, which reduce the simulation time without compromise of accuracy. At the second level of design, six diodes along with delta-delta a...
متن کاملDifferential Protection for Arbitrary Three-Phase Power Transformers
This thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection for such applications is considered impossible in ...
متن کاملHVDC Transmission with STATCOM
Most of the HVDC power converters with thyristor valves are assembled in a converter Bridge of Six pulse configuration. Converter transformers with one DC side winding as an ungrounded star connection and the other a delta configuration. Comparative studies of the two systems of HVDC CIGRE model without STATCOM and with STATCOM were performed. In these case, the consideration was the converter ...
متن کاملInvestigation of Power Factor Behavior in AC Railway System Based on Special Traction Transformers
The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unbalance loading are investigated simultaneously for electrical railway systems. Special traction transformers (i.e. single-phase, V/V, Wye-Delta, Scott, and Le Blanc) are used betwee...
متن کامل