Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom.
نویسندگان
چکیده
PURPOSE To compare single-detector row computed tomography (CT) and multi-detector row CT by using an experimental phantom containing a contrast-detail modulus for detection of low-contrast structures to optimize acquisition protocols. MATERIALS AND METHODS The parameters milliampere seconds, reconstructed section thickness, and elementary collimation for multi-detector CT were varied for two pitches with single- and multi-detector CT. For objective assessment of image quality, contrast-to-noise ratio (CNR) was calculated for an 8-HU low-contrast 15-mm-diameter object. Subjective assessment of image quality was performed by means of visual detection of low-contrast objects of various sizes by four independent observers. For each acquisition protocol, the effective doses required to obtain the CNR thresholds allowing 100% detection of 5-, 7-, and 9-mm-diameter objects were compared at single- and multi-detector CT at comparable section sensitivity profile with analysis of variance. RESULTS Significant correlation was found between CNR measurements and subjective object detection (r = 0.95, P <.05). CNRs of 1.0, 0.8, and 0.6 were required to detect 100% of the 5-, 7-, and 9-mm-diameter objects, respectively. For reconstructed section thickness of 5-10 mm, comparable x-ray doses were required with single- and multi-detector CT to detect objects. For reconstructed sections thinner than 5 mm, single- and multi-detector CT allowed detection of only the 7- and 9-mm-thick objects, but a higher x-ray dose was required for multi- than for single-detector CT (P <.05). CONCLUSION Multi-detector CT is less effective than single-detector CT in detection of small low-contrast objects if sections thinner than 5 mm are used. Results for single- and multi-detector CT were similar for sections 5 mm or thicker.
منابع مشابه
Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.
PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملSpatial variation of resolution and noise in multi-detector row spiral CT.
RATIONALE AND OBJECTIVES The authors performed this study to evaluate an approach for measuring the variations of three-dimensional spatial resolution and image noise throughout a field of view imaged with multi-detector row spiral computed tomographic (CT) scanners. MATERIALS AND METHODS The authors designed a phantom (diameter, 320 mm) that contained 37 metallic spheres (diameter, approxima...
متن کاملAn assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System
Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. Children are more sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be carried out periodically on the CT scanners. The aim of this research was to estimate the effective ...