Usability and performance characteristics of the pediatric air-Q® intubating laryngeal airway.

نویسندگان

  • Simon D Whyte
  • Erin Cooke
  • Stephan Malherbe
چکیده

PURPOSE The air-Q® intubating laryngeal airway (ILA) is a supraglottic device (SGD) designed specifically to function as both a primary airway and a bridging device and conduit for fibreoptic intubation in difficult airway scenarios. This observational study evaluated the usability and performance characteristics of pediatric air-Q ILA sizes 1.0, 1.5, 2.0, and 2.5 when used as a primary airway. METHODS One hundred ten children, American Society of Anesthesiologists physical status I-III and undergoing elective surgery, received a weight-appropriate air-Q ILA following induction of anesthesia. The evaluation criteria included ease of insertion, quality of ventilation, presence of gastric insufflation, oropharyngeal leak pressures (OLPs) and maximum tidal volumes (VT max) in five different head positions, and fibreoptic view of the glottis. RESULTS For sizes 1.0, 1.5, 2.0, and 2.5, the median [P25,P75] neutral OLPs (cm H2O) were 23.0 [20.0,30.0], 16.5 [15.0,20.8], 14.0 [10.0,17.8], and 14.0 [11.3,16.8], respectively. The median [P25,P75] neutral VT max values (mL · kg(-1)) were 17.4 [14.3,19.7], 20.3 [16.8,25.5], 17.8 [14.5,22.1], and 14.0 [11.6,16.0], respectively. Median [P25,P75] ease of insertion scores (0-10; 0 = easiest ever, 10 = most difficult ever) were 1 [1,2], 2 [2,3], 2 [1,2.8], and 2 [2,3] respectively. Ventilation was adequate in 108/110 cases, and a fibreoptic view of the vocal cords was obtained in 102/110 cases. CONCLUSIONS The air-Q ILA functions acceptably as a primary SGD in infants and children. The OLPs are lower than published values for the ProSeal laryngeal mask airway (LMA ProSeal™), the current pediatric SGD of choice, but adequate tidal volumes are readily achievable. The fibreoptic views of the glottis portend well for fibreoptic intubation through the device. (This trial was registered at clinicaltrials.gov number, NCT00885911).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The new air-Q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: a case series.

The air-Q intubating laryngeal airway (ILA) is a new supraglottic airway device which may overcome some limitations inherent to the classic laryngeal mask airway for tracheal intubation. We present a case series of patients with anticipated difficult airway in whom the air-Q ILA was successfully used as a conduit for fiberoptic intubation.

متن کامل

Successful tracheal intubation through an intubating laryngeal airway in pediatric patients with airway hemorrhage.

BACKGROUND This case report describes the use of the air-Q intubating laryngeal airway (air-Q ILA; Cookgas LLC, St. Louis, MO) for airway rescue and a conduit for blind tracheal intubation in two pediatric patients with failed rapid sequence intubation and difficult airways secondary to airway bleeding in the emergency department (ED). OBJECTIVES To describe the use of a new supraglottic resc...

متن کامل

Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis

Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis....

متن کامل

Use of the air-Q intubating laryngeal airway for rapid-sequence intubation in infants with severe airway obstruction: a case series.

We describe a four-step method for fibreoptic-guided, rapid-sequence tracheal intubation through the air-Q intubating laryngeal airway in infants with severe airway obstruction. Our step-wise process provides an organised and controlled approach to safely securing the airway.

متن کامل

A randomized trial comparing the Ambu ® Aura-i ™ with the air-Q ™ intubating laryngeal airway as conduits for tracheal intubation in children.

OBJECTIVES To assess the clinical performance of the Ambu Aura-i (Aura-i) in children. AIM To compare the Aura-i with the air-Q intubating laryngeal airway (air-Q) for the purposes of fiberoptic-guided tracheal intubation. BACKGROUND The Aura-i is a new supraglottic airway designed for tracheal intubation. MATERIALS/METHODS One hundred twenty children, ages 1 month to 6 years, were random...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 2013