Hemodynamic performance and inflammatory response during the use of VAD-InCor as a bridge to transplant.

نویسندگان

  • João Galantier
  • Luiz Felipe P Moreira
  • Anderson Benício
  • Adolfo A Leirner
  • Idágene Cestari
  • Edmar A Bocchi
  • Fernando Bacal
  • Noedir A G Stolf
چکیده

BACKGROUND Cardiac transplantation faces the serious problem of lack of donors and it is estimated that 20 to 40% of the patients die while waiting for heart transplantation. For these patients, the use of mechanical circulatory assist devices is the only choice of survival while waiting for a donor. In Brazil, the experience with mechanical circulatory support is limited and there is no regular program regarding the use of these devices as a bridge to heart transplantation. OBJECTIVE To evaluate the hemodynamic performance and the systemic inflammatory response during the clinical use of the InCor-type ventricular assist device (VAD-InCor) as a bridge to heart transplantation. METHODS Between October 2003 and April 2006, 11 patients in the waiting list for heart transplantation presented hemodynamic deterioration due to refractory cardiogenic shock. Seven of these patients were submitted to VAD-InCor implantation for left ventricular assistance. The etiologic diagnosis was Chagas' disease in 5 patients and idiopathic dilated cardiomyopathy in 2. RESULTS The duration of left ventricular assistance ranged from 14 to 42 days (mean 26.2 days). During this period, the hemodynamic performance of the DAV-InCor was adequate to support a normal hemodynamic state. There was normalization of central venous oxygen saturation and serum lactate. Two patients were submitted to heart transplantation, while the other 5 patients died under assistance due to infection and multiple organ failure. CONCLUSION The performance of the VAD-InCor, in the hemodynamic behavior of the studied patients, was adequate for the maintenance of a satisfactory circulatory state during the studied period. There was improvement in the tissue perfusion parameters and maintenance of systemic inflammatory response signs. There was a high incidence of complications; however, complications related to the device, which could compromise the safety of its use, were not demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo assessment of hemocompatibility of a ventricular assist device in healthy swine.

OBJECTIVE To assess the hemocompatible performance of a novel implantable pneumatic ventricular assist device (VAD, Innovamédica, México) in healthy swine. The aim of this pilot study was first, to determine if short-term VAD implantation elicited remarkable inflammatory response above that expected from surgical trauma; and second, to assess if heparinized or passivated VAD coatings, in combin...

متن کامل

Effect of Link Slab on Seismic Response of Two Span Straight and Skew Bridges

Highway bridges are frequently constructed as simple span structures with steel or concrete girders and a cast-in-place concrete deck, spanning from one pier to another. At each end of the simple span deck, a joint is provided for deck movement due to temperature, shrinkage, and creep. Bridge deck joints are expensive and pose many problems with regard to bridge maintenance. Elimination of deck...

متن کامل

Cost-effectiveness of ventricular assist device therapy as a bridge to transplantation compared with nonbridged cardiac recipients.

BACKGROUND Current available treatment options for advanced heart failure include heart transplantation and ventricular assist device (VAD) therapy. This project aimed to evaluate the cost-effectiveness of a bridge-to-transplantation (BTT)-VAD approach relative to direct heart transplantation in transplant-eligible patients. METHODS AND RESULTS A Markov model was used to evaluate survival ben...

متن کامل

Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension.

OBJECTIVES Raised pulmonary artery pressure (PAP), trans-pulmonary gradient (TPG) and pulmonary vascular resistance (PVR) are risk factors for poor outcomes after heart transplant in patients with secondary pulmonary hypertension (PH) and may contraindicate transplant. Unloading of the left ventricle with an implantable left ventricular assist device (LVAD) may reverse these pulmonary vascular ...

متن کامل

Application of J-BMS to Performance Evaluation and Remaining Life Prediction of an Existing RC Bridge

This paper describes a method of performance evaluation and remaining life prediction for an aged reinforced concrete (RC) T-girder bridge by J-BMS RC version via close visual inspection data, and also verifies the assessment results obtained as outputs from the Bridge Rating Expert System (RC-BREX) which is a subsystem of the J-BMS, to evaluate the effectiveness of the system. The Bridge Manag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 91 5  شماره 

صفحات  -

تاریخ انتشار 2008