The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.
نویسندگان
چکیده
During extracorporeal circulation, the patient's blood is siphoned into the extracorporeal circuit (ECC) by gravity or may be assisted kinetically or by vacuum. In all instances, negative pressure is generated in the venous line, which can cause entrainment of air into the ECC at the cannulation site. The typical ECC uses a venous reservoir, membrane oxygenator, and arterial line filter, which together aid in removal of air that has entered the venous line and minimize the transmission of gaseous microemboli to the patient. Recently, several manufacturers have introduced low prime ECCs with component configurations that differ from conventional ECCs, including the omission of a venous reservoir. These configuration changes may change the ability of the circuit to handle air and therefore their ability to minimize gaseous microemboli. The purpose of this study was to test the ability of new low prime ECCs to remove air introduced into the venous line and minimize gaseous microemboli from entering the patient's circulation. Using a model of CPB, air was introduced into the venous line of a low prime ECC and a conventional CPB circuit. The detection of the gaseous microemboli produced was monitored distal to the oxygenator by an ultrasonic emboli detector to determine if venous air was able to traverse the ECC at varying rates of air introduction and blood flow. Data was collected using data acquisition software loaded on a personal computer. Gaseous microemboli levels detected in the arterial line of the low prime ECC were 8 to 10 times higher than the microemboli levels detected in the conventional ECC at all blood flow rates. Every effort should be made to minimize and prevent air from being entrained in the venous line of a low prime CPB circuit to minimize the risk of arterial gaseous microemboli generation.
منابع مشابه
The influence of vacuum assisted drainage on arterial line emboli.
We read with interest the article by Jones and colleagues entitled “How Effective are Cardiopulmonary Bypass Circuits at Removing Gaseous Microemboli” (1). Their invariable detection of gaseous microemboli (GME) distal to the cardiopulmonary bypass (CPB) arterial line filter after entrainment of air to the venous line is in complete agreement with our original report of the same phenomenon (2)....
متن کاملClinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.
The use of an arterial line filter (ALF) within the pediatric cardiopulmonary bypass (CPB) circuit is not a new concept. It has always presented the perfusionist with a circuit component that while valuable, increased prime volume. The purpose of this study was to evaluate the change in prime volume and emboli between a conventional oxygenator with separate ALF and a new generation oxygenator w...
متن کاملGaseous Emboli Removal Efficiency in Arterial Screen Filters: A Comparative Study
____________ _ Seven commercially available arterial filters were evaluated for their effectiveness in removing gaseous emboli produced by various sources. All filters were of the screen type and ranged from 2040 micron pore size. The first phase of the study consisted of an appraisal of carbon dioxide flushing to facilitate priming. Two filters of each type were used. The first filter was prim...
متن کاملIn vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.
The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. Thi...
متن کاملNovel emboli protection cannula during cardiac surgery: first animal study.
BACKGROUND Stroke after open heart surgery is a major cause of morbidity and mortality. Up to 60% of intraoperative cerebral events are caused by emboli generated by manipulations of the aorta during surgery. This is the first animal study evaluating the safety and efficacy of a novel aortic cannula designed to extract solid and gaseous emboli during cardiac surgery. METHODS Seven domestic pi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2004