Phakic intraocular lenses to correct high myopia: Adatomed, Staar, and Artisan.

نویسندگان

  • José L Menezo
  • Cristina Peris-Martínez
  • Angel L Cisneros
  • Rafael Martínez-Costa
چکیده

PURPOSE To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. SETTING La Fe University Hospital, Department of Ophthalmology, and the Fundación Oftalmológica del Mediterráneo, Valencia, Spain. METHODS In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was -15.39 diopters (D) +/- 2.83 (SD), -16.00 +/- 5.05 D, and -16.17 +/- 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The mean follow-up was 32.4 months (range 19 to 46 months) in the Adatomed group, 18.3 months (range 11 to 21 months) in the Staar group, and 121.4 months (range 38.4 to 154.3 months) in the Artisan group. At the follow-up examinations, intraocular pressure (IOP), IOL pigment deposits, cataract formation, and visual acuity were evaluated. RESULTS The best corrected and uncorrected visual acuities improved in all eyes. No significant differences in visual acuity improvement were observed with the 3 materials, although the improvement was somewhat greater in eyes with the Artisan and Staar IOLs. The difference in mean IOP between preoperatively and the last follow-up examination was 1.5 mm Hg in the Staar group, 1.3 mm Hg in the Adatomed group, and 1.7 mm Hg in the Artisan group (P =.36, P =.26, and P =.32, respectively). The incidence of pigment deposits was similar in the Adatomed and Staar groups, with deposits in 32 eyes (54.23%) and 8 eyes (38.1%), respectively. Anterior cataract formation was higher in the Adatomed group (44.06%) than in the Staar group (9.52%); nuclear cataract developed in 2 Adatomed eyes (1.46%) only. CONCLUSIONS There was a higher incidence of anterior subcapsular cataract formation in the Adatomed group than in the Staar group. Delayed cataract development and the cataract type in patients with Artisan IOLs indicate that age and axial length may be prognostic factors. Factors such as IOL design, material, and placement probably affect cataract formation in eyes with posterior chamber IOLs for high myopia, particularly the Adatomed IOL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior chamber phakic intraocular lenses to correct high myopia: a comparative study between Staar and Adatomed models.

PURPOSE To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma pri...

متن کامل

Rate of cataract formation in 343 highly myopic eyes after implantation of three types of phakic intraocular lenses.

PURPOSE To assess the feasibility of using phakic intraocular lenses (PIOL) to treat high myopia, and evaluate the incidence of cataract, comparing three different lens types. METHODS From 1989 to 2002, we implanted three different phakic intraocular lenses (PIOL) in 343 eyes of 232 patients; 231 eyes recieved an Ophtec (Worst-Fechner model, iris-claw), 89 an Adatomed (silicone posterior cham...

متن کامل

Implantation of an Artisan phakic intraocular lens for the correction of high myopia after penetrating keratoplasty.

We report 2 cases in which an Artisan phakic intraocular lens (IOL) (Ophtec) was used to successfully treat high myopia after penetrating keratoplasty (PKP). The first case was a 43-year-old man who had a manifest refraction of -13.75 +3.00 x 50 with a best corrected visual acuity (BCVA) of 20/40(-2) after PKP in the left eye. Approximately 9 months after implantation of the Artisan IOL, the ma...

متن کامل

Implantation of Artisan toric phakic intraocular lens following Intacs in a patient with keratoconus.

We report a 24-year-old man with bilateral keratoconus in whom Intacs (Addition Technology, Inc.) were implanted in both eyes. The procedure was followed by Artisan toric phakic intraocular lens (Ophtec) implantation to correct the residual myopic and astigmatic refractive error.

متن کامل

Correction of myopia of 7 to 24 diopters with the Artisan phakic intraocular lens: two-year follow-up.

PURPOSE To evaluate the safety and efficacy of the iris claw phakic intraocular lens (Artisan; Ophtec BV, Groningen, The Netherlands) in patients with high myopia. METHODS Between May 1999 and July 2001, 93 Artisan phakic intraocular lenses (IOLs) were implanted in 60 patients affected by high myopia. All patients underwent 24-month follow-up. The power of the lenses ranged from -7.5 to -22.0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2004