Facilitated surgical strategy in total arch replacement and descending aorta stent grafting with the E-vita open hybrid prosthesis.
نویسنده
چکیده
The patient is a 69-year-old male with a symptomatic, fusiform distal arch/proximal descending aortic aneurysm extending over 9 cm in length. As demonstrated in the CTscan, the distal arch aneurysm is 5.5 cm diameter with a newly detected symptomatic ventral sac extending to 6 cm in diameter, presenting as a penetrating aortic ulcer (PAU). The ascending aorta is ectatic to 4.5 cm. His risk factors include arterial hypertension and a stroke in 1994 without residual effects.
منابع مشابه
Overall Essen's experience with the E-vita open hybrid stent graft system and evolution of the surgical technique.
BACKGROUND The hybrid stent graft prosthesis E-vita open was designed and introduced by us in 2005 to avoid a two-stage surgical approach in the surgical treatment of complex thoracic aortic disease. Experience in ascending aortic and arch replacement with simultaneous stent grafting of the descending aorta was accumulated over the past 8 years. Facilitation of surgical technique by moving the ...
متن کاملA Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft.
We report a unique case of a 63-year-old female with extensive peripheral vascular disease who underwent a single-stage surgical repair of the aortic arch and descending thoracic aortic aneurysm utilizing the Jotec E-vita Open Plus hybrid stent graft system combined with antegrade deployment of a thoracic endograft via a median sternotomy.
متن کاملSurgical management of delayed retrograde type A aortic dissection following complete supra-aortic de-branching and stent-grafting of the transverse arch.
OBJECTIVES Hybrid endovascular procedures are rapidly evolving and have recently been adopted for high-risk patients deemed unsuitable for conventional aortic arch surgery. We describe here our initial experience with this technique, including the management of 2 patients who developed a retrograde type A aortic dissection post-de-branching. METHODS Between May 2010 and October 2012, 109 pati...
متن کاملOne-stage repair in complex multisegmental thoracic aneurysmal disease: results of a multicentre study.
OBJECTIVES Patients with thoracic aneurysmal disease involving the arch and the descending or thoracoabdominal aorta may require more than one surgical intervention. The results of one-stage repair using a hybrid stent-graft in the frozen elephant trunk manner are presented. METHODS Between January 2005 and March 2012, 113 (age 67 ± 10 years) of 358 registered patients in the International E-...
متن کاملDistal aortic surgery following arch replacement with a frozen elephant trunk.
OBJECTIVE The frozen elephant trunk technique allows the repair of concomitant aortic arch and proximal descending aortic pathology in a single stage by using a hybrid prosthesis consisting of a vascular graft with a distal stented end. There are patients, however, who will require a second distal operation despite this new technique due to progression of their aortic disease. It has been uncle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of cardiothoracic surgery
دوره 2 5 شماره
صفحات -
تاریخ انتشار 2013