Effects of pre-cooling and pre-heating procedures on cement polymerization and thermal osteonecrosis in cemented hip replacements.

نویسندگان

  • Chaodi Li
  • Steven Schmid
  • James Mason
چکیده

Numerical studies were performed to investigate bone cement polymerization, temperature history and thermal osteonecrosis in cemented hip replacements with finite element methods. In this paper, the effects of pre-cooling and pre-heating of the prosthesis and/or the cement prior to implantation were simulated. It was found that the cement polymerization initiated near the bone-cement interface and progressed toward the prosthesis when both the cement and prosthesis were initially at room temperature. When the prosthesis and/or cement were pre-cooled, a reduction of the peak temperature at the bone-cement interface resulted, and this may reduce thermal osteonecrosis. However, this also slowed the polymerization process, and may result in a weaker bone cement. If the prosthesis was significantly initially heated, bone cement polymerization reversed reaction direction, started from the cement-prosthesis interface and proceeded toward the bone. Such polymerization direction may reduce or eliminate the formation of voids at the cement-prosthesis interface. Numerical results also showed that pre-heating seemed unlikely to produce significant thermal damage to the bone. The method of pre-heating the prosthesis prior to implantation may decrease the likelihood of cement-prosthesis loosening and increase the life of total hip arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pre-heating of components in cemented total hip arthroplasty.

Fatigue fractures which originate at stress-concentrating voids located at the implant-cement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44 degrees C is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intra-operatively as 32.3 degrees C. A simulated fem...

متن کامل

The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue...

متن کامل

The Effects of Local Heating and Cooling of Arm on Maximal Isometric Force Generated by the Elbow Flexor Musculature in Male Subjects

Objectives: It is well known that neuromuscular function is temperature sensitive. Changing of muscle temperature can effect voluntary muscle contraction. The aim of this study was to investigate the effects of cooling and heating on maximal isometric force generated by the elbow flexor musculature in male subjects. Methods: Forty five healthy males encompassing 3 groups participated in the ...

متن کامل

Effects of Cemented Hip Stem Pre-heating on Stem Push-out Strength.

OBJECTIVE To determine the effect on ultimate push-out load and cement-stem surface shear strength of thermally manipulating the cobalt-chromium-molybdenum (CoCrMo) alloy stems of bone cement-stem constructs. METHODS Satin-finished CoCrMo alloy stems were allocated to the following three groups with the predetermined temperatures: T24, ambient (24 °C); T37, body (37 °C); and T44, pre-heated s...

متن کامل

Finite element study regarding the influence of the cement mantle thickness on the stress distribution in a cemented hip joint

The disrupted function of the hip joint can be restored by means of total hip arthroplasty (i.e. reconstructive surgery of the joint) THA. This is a widely used medical strategy with high succes rates, world wide [1,2]. Among the failure scenarios of THA, aseptic loosening represents the main reason for revision of cemented hip implants [3]. Studies have shown that the two most frequent ways fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 25 7  شماره 

صفحات  -

تاریخ انتشار 2003