Development of an LCD-Based Visual Field System

نویسندگان

  • Jin Ho Joo
  • Jihyoung Lee
  • Heecheon You
  • Jaheon Kang
چکیده

BACKGROUND The present study investigated the diagnostic effectiveness of an LCD-based visual field testing system (LVF) in comparison with the standard automated perimetry Humphrey Field Analyzer II-750i (HFA). METHODS A randomized controlled crossover study was conducted with 202 normal and 128 glaucomatous eyes using both LVF and HFA. The visual field testing systems were compared in terms of mean deviation (MD), pattern standard deviation (PSD), and area under the receiver operating characteristics curve (AUC) of MD and PSD differentiating the normal and glaucomatous eyes. RESULTS Significant correlations were found between MD measurements from LVF and those from HFA for normal eyes (r = 0.342) and glaucomatous eyes (r = 0.796); slightly higher significant correlations were identified between PSD measurements from LVF and those from HFA for normal eyes (r = 0.363) and glaucomatous eyes (r = 0.828). Furthermore, high AUCs of MD were found as 0.786 for LVF and 0.868 for HFA and AUCs of PSD as 0.913 for LVF and 0.932 for HFA. CONCLUSION The comparison results of the present study support the competence of LVF compared with HFA in visual field testing for early detection of glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of visual deprivation on synaptic plasticity of visual cortex

  TBS (Theta Burst Stimulation) and PBs (Primed Bursts) are among effective tetanic stimulations for induction of LTP in hippocampus. Recent studies have indicated that TBS is effective in LTP induction in layer III synapses of neocortex, only if applied to layer IV. However, the possibility of neocortical LTP induction using PBs, has not yet been investigated. Sensory deprivation greatly influ...

متن کامل

مقایسه میزان تابش های غیر یونساز نمایشگر های کریستال مایع با نمایشگرهای معمولی در دانشگاه علوم پزشکی همدان

Introduction & Objective: The use of computers and monitors (displays) has been developed due to their increasing capabilities. The presence of electromagnetic fields, infrared and ul-traviolet radiations has been proven around the display, which all of them have adverse ef-fects on human health. Therefore, this study was conducted to survey and compare the mentioned variables around the disp...

متن کامل

Design and development of a visual comfort questionnaire (VCQ) for employees in the workplace

Introduction: Visual comfort is an important and influential factor on safety, mental health, sleep quality, and musculoskeletal disorders of employees in the workplace. This study aimed to design and develop a questionnaire to assess the visual comfort of employees in the workplace. Methods: The study was performed on 101 participants (88 men and 13 women) in the food industry. First, the a...

متن کامل

The Development of a Training Expert System for TFT-LCD Defects Inspection

At present, the image quality of LCD panels has been determined subjectively by human visual inspection. In fact, the inspectors need to memorize a large number of instructions. The inspection tasks include a series of complicated procedures that increase the workload of the inspectors. This research focuses on the improvement of LCD inspection. The knowledge extracting of inspection data was t...

متن کامل

GSM based Water Management in Irrigation System Using ARM7

In India, agriculture plays an important role for development in food production. In our country, agriculture are depends on the monsoons which is not sufficient source of water. So the irrigation is used in agriculture field. In Irrigation system, depending upon the soil type, water is provided to plant. In this paper, automatic irrigation system based on ARMs and GSM module. The developed sys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2018