Development and validation of methods for environmental monitoring of cyclophosphamide in workplaces.
نویسندگان
چکیده
Methods to monitor contamination of workplaces with antineoplastic drugs have been developed and validated. Cyclophosphamide (CP) was used as a model compound as it is one of the most commonly used antineoplastic drugs. A wipe sampling method to detect contamination with CP at surfaces was developed. A personal air sampling method to sample gas and vapour on solid sorbent tubes and particles with filters was also developed. Wipe and filter samples were extracted and sorbent samples were eluted, all with ethyl acetate. The samples were analysed with liquid chromatography tandem mass spectrometry. (2)H(6)-labelled cyclophosphamide was used as an internal standard. The between-day precision was 2-5% for wipe samples, 4-6% for sorbent samples and 3-8% for filter samples. The limit of detection was 0.02 ng CP per sample for the wipe and filter methods and 0.03 ng CP per sample for the solid sorbent method. Wipe sampling on surfaces made of different materials resulted in mean recoveries between 78-106%. The desorption recovery was between 97-102% for the wipe samples, 97% for the sorbent samples and 101% for the filter samples. Samples were stable for up to 2 months at 5 degrees C and -20 degrees C and for about 2 d at room temperature. The developed methods were applied to the measurement of contamination with CP in a hospital pharmacy. Trace amounts of CP, 1.3 and 1.4 ng, were detected on surfaces in the pharmacy.
منابع مشابه
Biological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملBiological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملDevelopment and Validation of the Tools for Evaluating Awareness and Practice Related to Heat Stress among the Workers of Warm Workplaces
Introduction: Prevention of heat-related diseases requires the participation of the workers. For this reason, the aim of this study was the development and validation of the tools for evaluating awareness and practice related to heat stress among the workers of warm workplaces. Material and Methods: The various items and factors related to the awareness and practice of the workers were identif...
متن کاملDevelopment and Validation of a GC/MS Method for Simultaneous Determination of 7 Monoterpens in Two Commercial Pharmaceutical Dosage Forms
Terpenes are active constituents of many pharmaceutical dosage forms with naturalproducts origin. One of the challenges in developing dosage forms with herbal originis their standardization as pharmaceutical products. GC-Mass is the most decisive andreliable technique to fulfill the requirements in this regard. In the present study, a reliable,rapid, and accurate method was developed for determ...
متن کاملDevelopment and Validation of a GC/MS Method for Simultaneous Determination of 7 Monoterpens in Two Commercial Pharmaceutical Dosage Forms
Terpenes are active constituents of many pharmaceutical dosage forms with naturalproducts origin. One of the challenges in developing dosage forms with herbal originis their standardization as pharmaceutical products. GC-Mass is the most decisive andreliable technique to fulfill the requirements in this regard. In the present study, a reliable,rapid, and accurate method was developed for determ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 6 12 شماره
صفحات -
تاریخ انتشار 2004