Percutaneous Treatment of Recurrent In-Stent Restenosis of Carotid Artery Stenting: A Case Report and State-of-the-Art Review

نویسندگان

  • Giuseppe Di Gioia
  • Cosimo Marco Campanale
  • Simona Mega
  • Laura Ragni
  • Antonio Creta
  • Germano Di Sciascio
چکیده

BACKGROUND Restenosis after carotid artery stenting (CAS) is a poorly described phenomenon. Studies have reported a variable incidence ranging from 4% to 19.7% at 1 year of follow-up. Doppler Ultrasound (DUS) is now routinely used in the follow-up after CAS and endarterectomy with optimal accuracy in detecting significant restenosis, compared to digital subtraction angiography (DSA). CASE REPORT We reported the case of a 76-year-old patient with evidence of recurrent severe in-stent restenosis (ISR) of the left internal carotid artery (ICA). In April 2007, due to evidence at DUS of severe left ICA disease, the patient underwent CAS. In January 2009, due to DUS evidence of severe ISR, the patient underwent balloon angioplasty. In September 2011, DUS showed a severe ISR with a peak systolic velocity (PSV) of 436 cm/s; in June 2012 angiography showed a sub-expanded stent in the middle medial side with severe ISR (70%). Multiple inflations were performed and a slight residual sub-expansion of the lateral side of the stent was observed. Post-procedural DUS showed a reduction of PSV to 283 cm/s and 266 cm/s at 1-month follow-up. An increasing value (322 cm/s) was noticed at 3-month follow-up DUS, while at 6-month follow-up DUS showed an important increase to 483 cm/s. Strict follow-up was adopted because of the patient's refusal of further treatment. CONCLUSIONS Criteria for diagnosis of restenosis are not well established. The optimal treatment is still debated and no indications have been established, due to the lack of sufficient data. Approaches to ISR include percutaneous transluminal angioplasty, cutting-balloon angioplasty (CB-PTA), stenting, and drug-eluting balloon (DEB) angioplasty. Several studies indicate that endovascular treatment, including balloon angioplasty and (CB-PTA) alone or in conjunction with stenting, is the preferred strategy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent

In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Challenging case of Muscle Bridge; a 15-year follow-up of a patient

Background: Anatomically myocardial bridging (MB) consists of either superficial myocardial fibers that traverse over the LAD or deep fibers that encircle the coronary artery. In this study, we present a patient with myocardial bridging, who was primarily diagnosed with coronary artery disease which did not properly respond to full-dose medical treatment but benefited from coronary artery bypas...

متن کامل

In-stent Restenosis after Carotid Artery Stenting: from Diagnosis to Treatment

Although carotid artery stenting is a safe and effective treatment for preventing ischaemic stroke in significant carotid atherosclerotic disease, it can be complicated by in-stent restenosis (ISR). Factors involved in the ISR process are both mechanical and patient-related, but the most important is the neointimal thickening within stent struts, leading to lumen reduction. Overall incidence of...

متن کامل

Carotid endarterectomy for in-stent restenosis: a case report and literature review

It is relatively difficult to treat restenosis when restenosis occurs following carotid artery stenting. Endarterectomy with simultaneous stent removal is an effective approach when restenosis occurs. The treatment method is still not well known. The present paper reports a case of restenosis after stenting that was treated with endarterectomy with a satisfactory treatment outcome. The patient,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015