FPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy
نویسندگان
چکیده
This paper deals with reconfigurable back-to-back converter topology and control orders in Wind Energy Conversion Systems (WECS). A typical WECS with Doubly Fed Induction Generator (DFIG) in balanced conditions is concerned. Based on the classical topology, a fault tolerant converter without any redundancy has been studied. The presented fault tolerant topology allows a “five-leg” structure with converters reconfiguration after switch failure detection. Furthermore, the control strategy for classical topology can no longer be applied after fault occurrence. Thus, a “five-leg” control strategy has also been proposed. The validation of the reconfigurable digital controller for the studied WECS with DFIG topology has been performed using a Hardware-in-the-Loop (HIL) reconfigurable platform including a Field Programmable Gate Array (FPGA) chip. HIL simulation results in both healthy and fault conditions have been presented to show simultaneously the viability of the studied converters topology and the reconfigurable control. 2012 Elsevier Ltd. All rights reserved.
منابع مشابه
Sensor Fault Tolerant Control For DFIG With WECS
Wind Energy Conversion Systems are the most striking renewable energy resources available to generate the electricity. Doubly-fed Induction Generator (DFIG) based wind turbine with variable speed is the most common wind turbine in the growing wind market. In any WECS, power flow must be maintained at all instant irrespective of any fault in the system. This paper deals with fault tolerant contr...
متن کاملFault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
In this paper, a new open-switch fault diagnosis method is proposed for the six-phase AC-DC converter based on the difference between the phase current and the corresponding reference using an adaptive threshold. The open-switch faults are detected without any additional equipment and complicated calculations, since the proposed fault detection method is integrated with the controller required ...
متن کاملCo - design of Fault - Tolerant Systems with Imperfect Fault Detection
In recent decades, transient faults have become a critical issue in modern electronic devices. Therefore, many fault-tolerant techniques have been proposed to increase system reliability, such as active redundancy, which can be implemented in both space and time dimensions. The main challenge of active redundancy is to introduce the minimal overhead of redundancy and to schedule the tasks. In m...
متن کاملDynamic Performance Of DFIG Based WECS Under Different Voltage Sag
At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...
متن کاملCoordinated Control of a Doubly-Fed Induction Generator-Based Wind Farm and a Static Synchronous Compensator for Low Voltage Ride-through Grid Code Compliance during Asymmetrical Grid Faults
This paper aims to explore a viable solution for a doubly-fed induction generator (DFIG)-based wind farm to meet the reactive support requirement of the low voltage ride-through (LVRT) grid code with safe grid-connected operation during asymmetrical grid faults. First, the control scheme for the DFIG-based wind energy conversion system (WECS) is designed. Then, the controllability issue is anal...
متن کامل