Legionella spp. in Puerto Rico cooling towers.
نویسندگان
چکیده
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10(5) cells per ml, which is within the range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.
منابع مشابه
Abundance and distribution of Legionellaceae in Puerto Rican waters.
Waters in marine and freshwater areas of Puerto Rico were analyzed for the presence of Legionella spp. by direct fluorescent antibody assay with guinea pig confirmation. Several species, including L. bozemanii, L. dumoffii, L. gormanii, L. longbeachae, L. micdadei, and L. pneumophila, were widely distributed among all sites. Legionellaceae, including L. pneumophila, were found in high densities...
متن کاملAn alkaline approach to treating cooling towers for control of Legionella pneumophila.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances...
متن کاملAn international trial of quantitative PCR for monitoring Legionella in artificial water systems
AIMS To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae. METHODS AND RESULTS Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were mo...
متن کاملEmerging Mycobacteria spp. in Cooling Towers
mydia sequanensis, a new intracellular Chlamydiales isolated from Seine river water using amoebal co-culture.lence of different Chlamydia-like organisms in an asymptomatic population. Clin Microbiol Infect. In press 2008. To the Editor: The importance of nontuberculous mycobacteria (NTM) in various clinical situations recently has increased. Members of the My-cobacterium avium complex (MAC) cau...
متن کاملLegionella species isolated from cooling towers in Kuala Lumpur.
Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 54 10 شماره
صفحات -
تاریخ انتشار 1988