A Versatile, Bar-Coded Nuclear Marker/Reporter for Live Cell Fluorescent and Multiplexed High Content Imaging

نویسندگان

  • Irina Krylova
  • Rachit R. Kumar
  • Eric M. Kofoed
  • Fred Schaufele
چکیده

The screening of large numbers of compounds or siRNAs is a mainstay of both academic and pharmaceutical research. Most screens test those interventions against a single biochemical or cellular output whereas recording multiple complementary outputs may be more biologically relevant. High throughput, multi-channel fluorescence microscopy permits multiple outputs to be quantified in specific cellular subcompartments. However, the number of distinct fluorescent outputs available remains limited. Here, we describe a cellular bar-code technology in which multiple cell-based assays are combined in one well after which each assay is distinguished by fluorescence microscopy. The technology uses the unique fluorescent properties of assay-specific markers comprised of distinct combinations of different 'red' fluorescent proteins sandwiched around a nuclear localization signal. The bar-code markers are excited by a common wavelength of light but distinguished ratiometrically by their differing relative fluorescence in two emission channels. Targeting the bar-code to cell nuclei enables individual cells expressing distinguishable markers to be readily separated by standard image analysis programs. We validated the method by showing that the unique responses of different cell-based assays to specific drugs are retained when three assays are co-plated and separated by the bar-code. Based upon those studies, we discuss a roadmap in which even more assays may be combined in a well. The ability to analyze multiple assays simultaneously will enable screens that better identify, characterize and distinguish hits according to multiple biologically or clinically relevant criteria. These capabilities also enable the re-creation of complex mixtures of cell types that is emerging as a central area of interest in many fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-throughput, image-based screening of genetic variant libraries

Image-based, high-throughput, high-content screening of pooled libraries of genetic perturbations will greatly advance our understanding biological systems and facilitate many biotechnology applications. Here we introduce a high-throughput screening method that allows highly diverse genotypes and the corresponding phenotypes to be imaged in numerous individual cells. To facilitate genotyping by...

متن کامل

Quantitative multispectral analysis following fluorescent tissue transplant for visualization of cell origins, types, and interactions.

With the desire to understand the contributions of multiple cellular elements to the development of a complex tissue; such as the numerous cell types that participate in regenerating tissue, tumor formation, or vasculogenesis, we devised a multi-colored cellular transplant model of tumor development in which cell populations originate from different fluorescently colored reporter gene mice and ...

متن کامل

A New Reporter Gene Technology: Opportunities and Perspectives

The paper summarizes the current status of the reporter gene technology and their basics. Reporter gene technology is widely used to monitor cellular events associated with gene expression and signal transduction. Based upon the splicing of transcriptional control elements to a variety of reporter genes, it “reports” the effects of a cascade of signaling events on gene expression inside cells. ...

متن کامل

High-content super-resolution imaging of live cell by uPAINT.

In this chapter, we present the uPAINT method (Universal Point Accumulation Imaging in Nanoscale Topography), a simple single-molecule super-resolution method which can be implemented on any wide field fluorescence microscope operating in oblique illumination. The key feature of uPAINT lies in recording high numbers of single molecules at the surface of a cell by constantly labeling while imagi...

متن کامل

An R-CaMP1.07 reporter mouse for cell-type-specific expression of a sensitive red fluorescent calcium indicator

Genetically encoded calcium indicators (GECIs) enable imaging of in vivo brain cell activity with high sensitivity and specificity. In contrast to viral infection or in utero electroporation, indicator expression in transgenic reporter lines is induced noninvasively, reliably, and homogenously. Recently, Cre/tTA-dependent reporter mice were introduced, which provide high-level expression of gre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013