Probes for spot measurement of surface conductivity on polluted insulators

نویسندگان

  • Krystian Leonard Chrzan
  • Masoud Farzaneh
چکیده

The surface conductivity of insulators in the field is usually very non-uniformly distributed. In this case the integral surface conductivity is not an appropriate parameter of pollution severity. A better evaluation can be achieved on the basis of local conductivity measurements by means of special probes, e.g. the rod probe or tissue strip probe. In this paper the form factors of different probes are given, and the influence of wet-contamination area, the meniscus and the pollution layer thickness on the measured value of surface conductivity are shown. It was found that the surface conductivity on polluted silicone rubber measured by a tissue strip probe is proportional to the Equivalent Contamination Deposit Density ECDD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leakage Current Based Thermal Modeling of Glass Disc Insulator Surface

The stability of transmission lines relies on the health of the insulators, such as glass string insulators, which may occasionally flashover during an overvoltage. The likelihood of flashover increases notably when the glass insulator is wrapped by a wet contaminant layer. In this paper a study of the surface thermal profile of glass disc insulators insulation had been carried out for both cle...

متن کامل

Performance Improvement of the Ceramic Outdoor Insulators Located at Highly Polluted Environment Using Room Temperature Vulcanized Silicone Rubber Coating

Ceramic insulators are widely used in transmission as well as in distribution lines. As outdoor insulators, the ceramic insulators are subjected to environmental stresses. In particular case, the insulators may severe high pollution exposure. Under the polluted condition, high leakage current will flow on the insulator surface and dry band arching may take place. The phenomena may initiate the ...

متن کامل

Computation of AC flashover voltage of polluted HV insulators using a dynamic arc model

Flashover of polluted insulators is still a serious threat to the safe operation of a power transmission system. Despite the extensive investigations carried out on the pollution performance of the insulators, the flashover characteristics are not well understood. Recent theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which c...

متن کامل

Direct measurement of surface-state conductance by microscopic four-point probe method

For in situ measurements of local electrical conductivity of well defined crystal surfaces in ultrahigh vacuum, we have developed microscopic four-point probes with a probe spacing of several micrometres, installed in a scanningelectron-microscope/electron-diffraction chamber. The probe is precisely positioned on targeted areas of the sample surface by using piezoactuators. This apparatus enabl...

متن کامل

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005