Analysis of saddle-node and Hopf bifurcations in IFOC drives due to errors in the estimate of the rotor time constant is presented. Experimental results showing such bifurcations are given and guidelines for drive commissioning are derived from these results.
منابع مشابه
Sensorless Indirect Field Oriented Control of Single-sided Linear Induction Motor With a Novel Sliding Mode MRAS Speed Estimator
This paper proposes a new sliding mode control (SMC) based model reference adaptive system (MRAS) for sensorless indirect field oriented control (IFOC) of a single-sided linear induction motor (SLIM). The operation of MRAS speed estimators dramatically depends on adaptation mechanism. Fixed-gain PI controller is conventionally used for this purpose which may fail to estimate the speed correctl...
متن کاملIndirect field-oriented control of induction motors is robustly globally stable
It is generally accepted that eld orientation, in one of its many forms, is an established control method for high dynamic performance AC drives. In particular, for induction motors indirect eld oriented control is a simple and highly reliable scheme which has become the de facto industry standard. In spite of its widespread popularity no rigorous stability proof for this controller was availab...
متن کاملOptimizing speed and angle control of stepping motor by using field oriented control
In the present study, field oriented control of step motor implementation has been analyzed sothat it can make a Sensorless control. Efficiency and Facilities of step motor is more than othertypes of electromotor. Therefore, the numbers of mechanisms and different types of turning canbe made into them. Also controlling these motors is easier than other available motors. Steppingmotor has been d...
متن کاملImprovement Performances of Active and Reactive Power Control Applied to DFIG for Variable Speed Wind Turbine Using Sliding Mode Control and FOC
This paper deals with the Active and Reactive Power control of double-fed induction generator (DFIG) for variable speed wind turbine. For controlling separately the active and the reactive power generated by a DFIG, field oriented control (FOC) and indirect sliding mode control (ISMC) are presented. These non linear controls are compared on the basis of topology, cost, efficiency. The main cont...
متن کاملRobustness margins for indirect field-oriented control of induction motors
The influence of the rotor time constant mismatch on the stability of induction motors under indirect field-oriented control is analyzed. The results of [14] are generalized. A Lyapunov function which provides a global stability test and allows us to compute robustness margins is given. Different mechanisms for the loss of stability are detected by means of bifurcation analysis. Robustness marg...