Thermal-Electric Finite Element Analysis and Experimental Validation of Bipolar Electrosurgical Cautery

نویسندگان

  • Robert E. Dodde
  • Scott F. Miller
  • James D. Geiger
  • Albert J. Shih
چکیده

Cautery is a process to coagulate tissues and seal blood vessels using heat. In this study, finite element modeling (FEM) was performed to analyze temperature distribution in biological tissue subject to a bipolar electrosurgical technique. FEM can provide detailed insight into the tissue heat transfer to reduce the collateral thermal damage and improve the safety of cautery surgical procedures. A coupled thermal-electric FEM module was applied with temperature-dependent electrical and thermal properties for the tissue. Tissue temperature was measured using microthermistors at different locations during the electrosurgical experiments and compared to FEM results with good agreement. The temperatureand compression-dependent electrical conductivity has a significant effect on temperature profiles. In comparison, the temperature-dependent thermal conductivity does not impact heat transfer as much as the temperature-dependent electrical conductivity. Detailed results of temperature distribution were obtained from the model. The FEM results show that the temperature distribution can be changed with different electrode geometries. A flat electrode was modeled that focuses the current density at the midline of the instrument profile resulting in higher peak temperature than that of the grooved electrode (105 versus 96°C). DOI: 10.1115/1.2902858

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Tissue Conductivity during High-frequency and Low-voltage Irreversible Electroporation

Introduction: Irreversible electroporation (IRE) is a process in which the membrane of the cancer cells are irreversibly damaged with the use of high-intensity electric pulses, which in turn leads to cell death. The IRE is a non-thermal way to ablate the cancer cells. This process relies on the distribution of the electric field, which affects the pulse amplitude, width, and electrical conducti...

متن کامل

Simulation and Experimental Study of Vibration and Noise of Pure Electric Bus Transmission based on Finite Element and Boundary Element Methods

Since the electric motor of pure electric vehicle replaced the engine, the "masking effect" disappears, and the problem of vibration and noise of the transmission becomes prominent. This is generated during the gear meshing and is transmitted to the housing through the shaft and bearing. Thereby, radiation noise of the housing are generated. The prediction and analysis...

متن کامل

Investigation on Forming of Titanium Bipolar Plates Using Micro-stamping Process

Micro-stamping process is one of the most cost-effective methods to manufacture metallic bipolar plates (BPPs). This research investigates the forming of titanium thin sheet as a potential candidate for BPPs in proton exchange membrane fuel cell (PEMFC). In this regard, the process was first simulated using finite element (FE) code Abaqus. Afterward, experimental tests were implemented and the ...

متن کامل

Analysis of Resistance Spot Welding Process Parameters Effect on the Weld Quality of Three-steel Sheets Used in Automotive Industry: Experimental and Finite Element Simulation

In the present research, the effects of spot-welding process parameters on the nugget diameter and electrode penetration depth of spot-welded joints were investigated. To achieve this, a spot-welded joint of three-thin sheet low carbon steels (same thicknesses of 0.8 mm) was simulated as an electerical-thermal-mechanical coupling of 3D finite element model. After validating the finite element s...

متن کامل

Electrosurgical units – how they work and how to use them safely

Compliance monitoring by eye care team • Ensure children wear their spectacles Refer children with complex refractive error and other eye conditions Electrosurgery is used routinely in eye surgery to cut, coagulate, dissect, fulgurate, ablate and shrink tissue. High frequency (100 kilohertz to 5 megahertz), alternating electric current at various voltages (200–10,000 Volts) is passed through ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008