Effect of light-curing units, post-cured time and shade of resin cement on knoop hardness.

نویسندگان

  • Rogério Vieira Reges
  • Ana Rosa Costa
  • Américo Bortolazzo Correr
  • Evandro Piva
  • Regina Maria Puppin-Rontani
  • Mário Alexandre Coelho Sinhoreti
  • Lourenço Correr-Sobrinho
چکیده

The aim of this study was to evaluate the Knoop hardness after 15 min and 24 h of different shades of a dual-cured resin-based cement after indirect photoactivation (ceramic restoration) with 2 light-curing units (LCUs). The resin cement Variolink II (Ivoclar Vivadent) shade XL, A2, A3 and opaque were mixed with the catalyst paste and inserted into a black Teflon mold (5 mm diameter x 1 mm high). A transparent strip was placed over the mold and a ceramic disc (Duceram Plus, shade A3) was positioned over the resin cement. Light-activation was performed through the ceramic for 40 s using quartz-tungsten-halogen (QTH) (XL 2500; 3M ESPE) or light-emitting diode (LED) (Ultrablue Is, DMC) LCUs with power density of 615 and 610 mW/cm(2), respectively. The Koop hardness was measured using a microhardness tester HMV 2 (Shimadzu) after 15 min or 24 h. Four indentations were made in each specimen. Data were subjected to ANOVA and Tukey's test (alpha=0.05). The QTH LCU provided significantly higher (p<0.05) KHN values than the LED LCU. When the post-cure times were compared for the same shade, QTH and LED at 24 h provided significantly higher (p<0.05) KHN values than at 15 min. It may be concluded that the Knoop hardness was generally dependent on the LCU and post-cure time. The opaque shade of the resin cement showed lower Knoop hardness than the other shades for both LCUs and post-cure times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hardening of dual-cure resin cements and a resin composite restorative cured with QTH and LED curing units.

OBJECTIVE The aim of this study was to determine the effects of light intensity and type of light unit (quartztungsten-halogen [QTH] or light-emitting diode [LED]) on the hardening of various resin cements and a resin composite restorative. METHODS Disk specimens were prepared from 4 dual-cured resin cements (Variolink II, Calibra, Nexus 2 and RelyX ARC). Two QTH light-curing units (Visilux 2...

متن کامل

Effect of curing mode on the hardness of dual-cured composite resin core build-up materials.

This study evaluated the Knoop Hardness (KHN) values of two dual-cured composite resin core build-up materials and one resin cement exposed to different curing conditions. Two dual-cured core build-up composite resins (LuxaCore-Dual, DMG; and FluoroCore2, Dentsply Caulk), and one dual-cured resin cement (Rely X ARC, 3M ESPE) were used in the present study. The composite materials were placed in...

متن کامل

Effect of light-curing methods on resin cement Knoop hardness at different depths.

This study evaluated, using Knoop hardness test, the polymerization depth of Rely-X dual-cured resin cement activated by chemical reaction alone (control group) or by chemical/physical mode with light curing through a 1.5-mm-thick ceramic layer (HeraCeram). Bovine incisors had their buccal surface flattened and hybridized. On this surface, a rubber mould (5 mm diameter; 1 mm high) was bulk fill...

متن کامل

Effect of thickness of indirect restoration and distance from the light-curing unit tip on the hardness of a dual-cured resin cement.

This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC fil...

متن کامل

Influence of Energy Density of Different Light Sources on Knoop Hardness of a Dual-cured Resin Cement

The purpose of this study was to evaluate the Knoop hardness of a dual-cured resin-based luting cement irradiated with different light sources as well energy density through a ceramic sample. Three light-curing unit (LCUs) were tested: tungsten halogen light (HAL), light-emitting diode (LED) and xenon plasma-arc (PAC) lamp. Disc-shaped specimens were fabricated from a resin-based cement (Enforc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2009