Biomimetic Total Knee Arthroplasty with Anterior Cruciate Ligament Preservation Restores Normal Kinematics and Reduces Implant Wear
نویسندگان
چکیده
Disclosures: T. Zumbrunn: None. K. Mangudi Varadarajan: 1; MAKO Surgical. 3A; MERCK (Spouse). 3B; Orthopedic Technology Group. H.E. Rubash: 1; MAKO Surgical, Pipeline. 3B; MAKO Surgical, Pipeline, Access Mediquip. 4; Pipeline, Orthopedic Technology Group. 7; Lippincott, Williams and Wilkins. H. Malchau: 1; Smith and Nephew, MAKO Surgical. 3B; Smith and Nephew, MAKO Surgical. 3C; Biomet. 4; RSA Biomedical, Orthopedic Technology Group. 5; Smith and Nephew, DePuy, Biomet, Zimmer, MAKO Surgical. 6; Smith and Nephew. G. Li: 1; MAKO Surgical. B. Micheli: None. K. Wannomae: None. O.K. Muratoglu: 1; Zimmer, Biomet, Corin, Conformis, MAKO Surgical. 2; Zimmer, Corin. 4; Orthopedic Technology Group. 5; Biomet, DePuy, MAKO Surgical.
منابع مشابه
The utility of bicruciate-retaining total knee arthroplasty
BACKGROUND We describe the features of modern and historical bicruciate-retaining (BCR) total knee arthroplasty (TKA) implants compared with other TKA implant designs, reviewing kinematics, proprioception, operative technique, and clinical results. METHODS We performed a review based on PubMed, Embase, CINAHL Plus, and Cochrane databases from January 1990 to April 2016 using combinations of t...
متن کاملWear Behavior of an Unstable Knee: Stabilization via Implant Design?
BACKGROUND Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. METHODS Two simulator wear tests were performed on a high-conforming total k...
متن کاملRelationship between Femoral Intercondylar Notch Narrowing on Radiography and Anatomical and Histopathologic Integrity of Anterior Cruciate Ligament in Patients Undergoing Total Knee Replacement Surgery
Abstract Introduction: The presence of cruciate ligaments are very important for normal knee kinematics. Knee arthroplasty prostheses, in which these ligaments are maintained, have better kinematics. The aim of the present study was to investigate the association between femoral intercondylar notch narrowing in radiography and clinical and histopathologic integrity of anterior cruciate li...
متن کاملPreservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model
OBJECTIVES Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in...
متن کاملEffect of joint laxity on polyethylene wear in total knee replacement.
Experimental simulator studies are frequently performed to evaluate wear behavior in total knee replacement. It is vital that the simulation conditions match the physiological situation as closely as possible. To date, few experimental wear studies have examined the effects of joint laxity on wear and joint kinematics and the absence of the anterior cruciate ligament has not been sufficiently t...
متن کامل