The heritability of corneal hysteresis and ocular pulse amplitude: a twin study.
نویسندگان
چکیده
PURPOSE To examine the roles of genetic and environmental factors in corneal hysteresis and ocular pulse amplitude by performing a classic twin study. DESIGN Cross-sectional twin study. PARTICIPANTS AND/OR CONTROLS Two hundred sixty-four twin pairs: 135 monozygotic (MZ) and 129 dizygotic (DZ). METHODS Corneal hysteresis was measured using the Reichert Ocular Response Analyzer (ORA; Reichert, Buffalo, NY), and ocular pulse amplitude was measured using the Pascal Dynamic Contour Tonometer (DCT; Swiss Microtechnology AG, Port, Switzerland). MAIN OUTCOME MEASURES Contribution of genetic and environmental effects on corneal hysteresis and OPA among MZ and DZ twins. RESULTS The mean corneal hysteresis was 10.24+/-1.54 mmHg and the mean ocular pulse amplitude was 2.88+/-0.97 mmHg. The MZ correlations were higher than DZ for both corneal hysteresis and ocular pulse amplitude (correlation coefficients, 0.75:0.42 and 0.59:0.32 for MZ:DZ twins, respectively). Modeling suggested heritability of corneal hysteresis of 0.77 (95% confidence interval [CI], 0.70-0.82), with the remaining proportion of variance because of individual environmental effects of 0.23 (95% CI, 0.18-0.30). For ocular pulse amplitude, the heritability was 0.62 (95% CI, 0.51-0.70), with the remaining proportion of variance the result of individual environmental effects of 0.38 (95% CI, 0.30-0.49). CONCLUSIONS This study demonstrated that additive genetic influences explained most of the individual differences in corneal hysteresis and ocular pulse amplitude among these twins.
منابع مشابه
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملویژگیهای بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری
Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...
متن کاملThe Heritability of Glaucoma-Related Traits Corneal Hysteresis, Central Corneal Thickness, Intraocular Pressure, and Choroidal Blood Flow Pulsatility
PURPOSE The purpose of this work was to investigate the heritability of potential glaucoma endophenotypes. We estimated for the first time the heritability of the pulsatility of choroidal blood flow. We also sought to confirm the heritability of corneal hysteresis, central corneal thickness, and 3 ways of measuring intraocular pressure. METHODS Measurements were performed on 96 first-degree r...
متن کاملCorneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients.
PURPOSE To investigate relationships between acute intraocular pressure (IOP)-induced optic nerve head surface deformation and corneal hysteresis and thickness in glaucomatous and nonglaucomatous human eyes. METHODS This was a prospective experimental study of 100 subjects (38 with glaucoma, 62 without glaucoma). Data collected included spherical equivalent, optic disc diameter, central corne...
متن کاملHeritability of myopia and ocular biometrics in Koreans: the healthy twin study.
PURPOSE To estimate the heritabilities of myopia and ocular biometrics among different family types among a Korean population. METHODS We studied 1508 adults in the Healthy Twin Study. Spherical equivalent, axial length, anterior chamber depth, and corneal astigmatism were measured by refraction, corneal topography, and A-scan ultrasonography. To see the degree of resemblance among different ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 115 9 شماره
صفحات -
تاریخ انتشار 2008