Clinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study.

نویسندگان

  • Jorge L Alio
  • David P Piñero
  • Albert Daxer
چکیده

PURPOSE To evaluate the clinical outcomes after implantation of the MyoRing (DIOPTEX GmBH, Linz, Austria) by means of femtosecond laser technology in eyes with corneal ectasia. DESIGN Retrospective, consecutive, nonrandomized, case series. PARTICIPANTS A total of 12 eyes of 11 patients with ages ranging from 17 to 50 years were included. All cases were diagnosed with corneal ectasia according to the standard criteria: 1 case of post-LASIK ectasia and 11 cases of keratoconus. All cases presented with reduced best spectacle-corrected visual acuity, contact lens intolerance or discomfort, and central corneal thickness of more than 350 μm. METHODS MyoRing inserts of 280 μm in thickness and 5 mm in diameter were implanted in all cases into an intrastromal corneal pocket created by means of femtosecond technology. Visual, refractive, corneal topography, and pachymetric changes were evaluated during a 6-month follow-up. In addition, corneal biomechanical changes were evaluated by means of the Ocular Response Analyzer (Reichert, Buffalo, NY). MAIN OUTCOME MEASURES Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, keratometry, corneal asphericity, corneal higher-order aberrations, pachymetry, corneal hysteresis (CH), and corneal resistance factor (CRF). RESULTS A significant improvement in UDVA was observed 1 week after surgery (P=0.001), which was consistent with the significant reduction in sphere (P=0.002) and cylinder (P=0.004). No significant changes were detected in these parameters afterward (P ≥ 0.263). Furthermore, a significant corneal flattening of a mean value of 8.03 diopters (D) was found (P=0.005). This keratometric change was correlated with the magnitude of corneal coma-like aberrations (r=0.830, P=0.003) and the CRF (r=-0.782, P=0.008). In regard to aberrometry, a statistically significant increase in primary spherical aberration was found 1 month after surgery (P=0.001). In addition, a significant reduction in higher-order corneal aberrations was found 3 to 6 months after surgery (P=0.027). Significant corneal thickening was also observed postoperatively in the central, nasal, and temporal areas (P ≤ 0.013). No statistically significant changes were detected (P ≥ 0.176) in corneal biomechanics. Explantation was performed in a very advanced keratoconus because of the extremely poor visual outcome. CONCLUSIONS MyoRing implantation using femtosecond technology in keratoconus allows successful corneal modeling, although the use of large diameters is advisable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femtosecond assisted intrastromal corneal ring (ISCR) implantation for the treatment of corneal ectasia.

PURPOSE To assess the outcomes of intrastromal corneal ring (ISCR) implantation for the treatment of corneal ectasia. METHODS Thirty-five consecutive patients with secondary corneal ectasia treated with keraring intrastromal corneal ring segment implantation aided by intralaser femtosecond technique (K-ICRS-FS) were evaluated. Visual acuity (logMAR), refraction and astigmatism vector analysis...

متن کامل

Prediction of Corneal Condition After Corneal Ring Implantation in Keratoconus Patients

Background: Keratoconus is a common complication among corneal defects. As a result of expeditious and extensive progress of medical science in recent decades, corneal ring implantation has turned into a successful surgical procedure to correct the vision of Keratoconus patients; however, selecting the right patient is essential in the success of the operation. The prediction of corneal conditi...

متن کامل

Actual Indications for Intracorneal Ring Segment Implantation in Keratoconus

Intracorneal ring segments (ICRS) are small synthetic implements designed to achieve refractive adjustment by flattening the cornea. Three common types of commercially available ICRS are Intacs, Keraring and Ferrara rings. Low myopia was the initial indication for implantation of ICRS, and indications later included ectatic corneal diseases (such as keratoconus and pellucid marginal degeneratio...

متن کامل

Corneal aberrometric and refractive performance of 2 intrastromal corneal ring segment models in early and moderate ectatic disease.

PURPOSE To evaluate and compare visual, refractive, and corneal aberrometric outcomes after implantation of 2 types of intrastromal corneal ring segments (ICRS) in eyes with early to moderate ectatic disease. SETTINGS Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS This retrospective analysis comprised consecutive eyes with grade I or grade II corneal ectasi...

متن کامل

Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up

PURPOSE We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the peri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 118 7  شماره 

صفحات  -

تاریخ انتشار 2011