Thoracic and Abdominal Abnormalities Found on Raw Data Images of Cardiac SPECT
نویسنده
چکیده
Received 3/25/2005; revised 4/2/2005; accepted 4/8/2005. For correspondence or reprints contact: Wei-Jen Shih, M.D., Nuclear Medicine Service, 1101 Veterans Drive, VA Medical Center, Lexington KY, USA. Tel: (606) 381-5928, Fax: (606) 323-2171, E-mail: [email protected] During acquisition of Tc labeled perfusion agents or Tl-thallous chloride (Tl) gated cardiac SPECT the field area covered includes the essential organs of the body, encompassing the organs or tissues of the thorax and the abdomen. Tl can be localized in benign and malignant lesion, and Tc-tetrofosmin is mostly excreted through hepatobiliary system, the raw data images at one hour may be considered as hepatobiliary scintigram using such as Tc-Choletec. Thus raw data images of dual isotope or 2-day Tc-tetrofosmin cardiac SPECT allow us to view the abnormality in the thorax and/or abdomen. Abnormalit ies above the diaphragm and chest wall include: (1) malignant or benign lesion(s) in the lungs; (2) pleural effusion; (3) pericardial effusion; (4) diffuse and bilateral pulmonary uptake; (5) sternal uptake in anemia and/or hypoxemia; (6) duodenogastroesophageal reflux; (7) hiatus hernia; (8) lucent lungs; (9) mediastinal tumor: atypical carcinoid tumor; and (10) breast cancer. Abnormalities of the diaphragm may include: (1) elevation of the right diaphragm and (2) displacement of the diaphragm on both sides. Abnormal findings below the diaphragm include: (1) hepatomegaly; (2) splenomegaly; (3) cirrhosis of the liver with ascites; (4) vertebral uptake in anemia and/or hypoxemia; and (5) a focal avascular lesion. It is emphasized that: (1) multiple abnormalities in the thorax and/or abdomen may exist as demonstrated by one patient’s raw data images; (2) viewing raw data images should be included as part of cardiac SPECT interpretation; and (3) abnormal findings should also be included in the report to alert clinicians to further investigation if clinically indicated.
منابع مشابه
The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملReview of transmission scanning configurations in cardiac SPECT
The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...
متن کاملDuodenogastric reflux in a hiatal hernia seen as retrocardiac activity on 99mTc-tetrofosmin cardiac SPECT raw-data images.
We present a patient with a large hiatal hernia resulting in duodenogastric reflux that was seen as abnormal activity below and behind the heart (retrocardiac) on SPECT images and on (99m)Tc-tetrofosmin cardiac SPECT raw-data projection images. Incidental findings such as extra- and retrocardiac activity in the thorax and abdomen should be included on all comprehensive cardiac SPECT reports.
متن کاملPlatelet-based MPLE algorithm for denoising of SPECT images: phantom and patient study
Introduction: In this study the evaluation of a Platelet-based Maximum Penalized Likelihood Estimation (MPLE) for denoising SPECT images was performed and compared with other denoising methods such as Wavelets or Butterworth filtration. Platelet-based MPLE factorization as a multiscale decomposition approach has been already proposed for better edges and surfaces representation due to Poi...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...