Histological examination of vascular damage caused by stent retriever thrombectomy devices.

نویسندگان

  • Daisuke Arai
  • Akira Ishii
  • Hideo Chihara
  • Hiroyuki Ikeda
  • Susumu Miyamoto
چکیده

BACKGROUND AND OBJECTIVES Although the recently marketed stent retriever thrombectomy devices have demonstrated a high recanalization rate and favorable clinical outcomes, there is a concern about the risks of intimal injuries when pulling out the stent in the unfolded position. In this study, the Solitaire Flow Restoration System and the Trevo retriever were used in a histopathological comparison of vascular injuries caused by stent retriever thrombectomy devices. METHODS Rabbit carotid arteries were used in the experiments with stent retriever thrombectomy devices. Carotid artery samples were harvested either 1 or 2 weeks postoperatively for histological examination. RESULTS Histological changes caused by the use of stent retriever thrombectomy devices were observed from the intimal to medial layers. With the Solitaire FR 4 mm, intimal and medial thickening was observed 1 week postoperatively, and progression of intimal thickening was observed 2 weeks postoperatively. The extent of intimal thickening tended to be greater with the Solitaire FR 6 mm than with the Solitaire FR 4 mm, but this difference was not significant. Compared with the Solitaire FR 4 mm, the Trevo had a significantly smaller area of intimal thickening. CONCLUSIONS Although there are some differences among devices, results from this study indicate that stent retriever thrombectomy devices induce vascular damage that extends to the medial layer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increasing Efficacy of Thrombectomy by Using Digital Subtraction Angiography to Confirm Stent Retriever Clot Integration

Physicians performing thrombectomy for acute stroke have had increasing success as thrombectomy-specific devices have continued to evolve. As the devices evolve, so too must the techniques. The current generation of stent retriever thrombectomy devices requires five minutes of dwell time, regardless of the particularities of the case. We have noticed the presence of flow through the stent immed...

متن کامل

Endovascular Stroke Therapy Focused on Stent Retriever Thrombectomy and Direct Clot Aspiration: Historical Review and Modern Application

Intravenous recombinant tissue plasminogen activator had been the only approved treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time window, numerous contraindications, and its low recanalization rate were all limitations of this modality. Under those circumstances, endovascular stroke therapy went through a great evolution during the past two decades of...

متن کامل

Thrombectomy for delayed basilar stent occlusion with good outcome.

ABSTRACT Neurovascular stents have revolutionized the endovascular treatment of wide-necked and fusiform aneurysms; however, potential in-stent thrombosis-resulting in devastating strokes-complicates their use. Interventionalists using these devices must be aware of treatment options for such events. We present the case of a 46-year-old man who underwent stent-supported embolization of an incid...

متن کامل

Multimodal 3 Tesla MRI confirms intact arterial wall in acute stroke patients after stent-retriever thrombectomy.

BACKGROUND AND PURPOSE The aim of this prospective study was to assess vascular integrity after stent-retriever thrombectomy. METHODS Dissection, contrast medium extravasation, and vasospasm were evaluated in 23 patients after thrombectomy with biplane or 3D-digital subtraction angiography and 3-Tesla vessel wall MRI. RESULTS Vasospasm was detected angiographically in 10 patients, necessita...

متن کامل

Comparative Analysis of Endovascular Stroke Therapy Using Urokinase, Penumbra System and Retrievable (Solitare) Stent

BACKGROUND Higher reperfusion rates have been established with endovascular treatment for acute ischemic stroke patients. There are limited data on the comparative performance of mechanical thrombectomy devices. This study aimed to analyse the efficacy and safety of the stent retriever device (Solitaire stent) by comparing procedure time, angiographic outcome, complication rate and long term cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurointerventional surgery

دوره 8 10  شماره 

صفحات  -

تاریخ انتشار 2016