Radiation dose to PET technologists and strategies to lower occupational exposure.
نویسندگان
چکیده
OBJECTIVE The use of PET in Australia has grown rapidly. We conducted a prospective study of the radiation exposure of technologists working in PET and evaluated the occupational radiation dose after implementation of strategies to lower exposure. METHODS Radiation doses measured by thermoluminescent dosimeters over a 2-y period were reviewed both for technologists working in PET and for technologists working in general nuclear medicine in a busy academic nuclear medicine department. The separate components of the procedures for dose administration and patient monitoring were assessed to identify the areas contributing the most to the dose received. The impact on dose of implementing portable 511-keV syringe shields (primary shields) and larger trolley-mounted shields (secondary shields) was also compared with initial results using no shield. RESULTS We found that the radiation exposure of PET technologists was higher than that of technologists performing general nuclear medicine studies, with doses averaging 771 +/- 147 and 524 +/- 123 microSv per quarter, respectively (P = 0.01). The estimated dose per PET procedure was 4.1 microSv (11 nSv/MBq). Injection of 18F-FDG contributed the most to radiation exposure. The 511-keV syringe shield reduced the average dose per injection from 2.5 to 1.4 microSv (P < 0.001). For the longer period of dose transportation and injection, the additional use of the secondary shield resulted in a significantly lower dose of radiation than did use of the primary shield alone or no shield (1.9 vs. 3.6 microSv [P = 0.01] and 3.4 microSv [P = 0.03], respectively). CONCLUSION The radiation doses currently received by technologists working in PET are within accepted occupational health guidelines, but improved shielding can further reduce the dose.
منابع مشابه
Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...
متن کاملEvaluation of Occupational Radiation Dose in One Year for Operators Working in CT Scan Centers
Introduction: Becuase of the most radiation dose receiving by human is related to medical radiation exposures, and also Computed Tomography (CT) is a special type of radiography that is one of the main method of radiation exposure today, and it's growing increasingly. Therefore, radio technologists working in CT scan imaging centers, are at risk of radiation. Due to the high am...
متن کاملEffects of Occupational Exposure on Blood Cells of Radiographers Working in Diagnostic Radiology Department of Khuzestan Province
Introduction: Because radiology technologists are exposed to protracted low-dose ionizing radiation and considering the possible effects of low-dose radiation on blood factors, we aimed to investigate the effects of occupational exposure on blood factors of radiographers working in radiology departments of Khuzestan Province, Iran. Materials and Methods: This case-control study was conducte...
متن کاملEvaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose
Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2005