Stroke type differentiation using spectrally constrained multifrequency EIT: evaluation of feasibility in a realistic head model.

نویسندگان

  • Emma Malone
  • Markus Jehl
  • Simon Arridge
  • Timo Betcke
  • David Holder
چکیده

We investigate the application of multifrequency electrical impedance tomography (MFEIT) to imaging the brain in stroke patients. The use of MFEIT could enable early diagnosis and thrombolysis of ischaemic stroke, and therefore improve the outcome of treatment. Recent advances in the imaging methodology suggest that the use of spectral constraints could allow for the reconstruction of a one-shot image. We performed a simulation study to investigate the feasibility of imaging stroke in a head model with realistic conductivities. We introduced increasing levels of modelling errors to test the robustness of the method to the most common sources of artefact. We considered the case of errors in the electrode placement, spectral constraints, and contact impedance. The results indicate that errors in the position and shape of the electrodes can affect image quality, although our imaging method was successful in identifying tissues with sufficiently distinct spectra.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting electrode modelling errors in EIT on realistic 3D head models.

Electrical impedance tomography (EIT) is a promising medical imaging technique which could aid differentiation of haemorrhagic from ischaemic stroke in an ambulance. One challenge in EIT is the ill-posed nature of the image reconstruction, i.e., that small measurement or modelling errors can result in large image artefacts. It is therefore important that reconstruction algorithms are improved w...

متن کامل

Correction of electrode modelling errors in multi-frequency EIT imaging.

The differentiation of haemorrhagic from ischaemic stroke using electrical impedance tomography (EIT) requires measurements at multiple frequencies, since the general lack of healthy measurements on the same patient excludes time-difference imaging methods. It has previously been shown that the inaccurate modelling of electrodes constitutes one of the largest sources of image artefacts in non-l...

متن کامل

Electrical impedance tomography spectroscopy (EITS) for human head imaging.

Electrical impedance tomography (EIT) is a recently developed medical imaging method which has practical advantages for imaging brain function as it is inexpensive, rapid and portable. Its principal use in validated human studies to date has been to image changes in impedance at a single excitation frequency over time, but there are potential applications where it is desirable to obtain images ...

متن کامل

Influence of heart motion on EIT-based stroke volume estimation

Cardiac electrical impedance tomography (EIT) signals are affected by myocardial motion. The feasibility of stroke volume estimation using such signals is thus questionable. Results based on a dynamic model show that myocardial motion indeed affects but does not compromise stroke volume estimation.

متن کامل

Effects of Warping Finite Element Meshes for the Forward Model of the Head in Eit

The use of realistic FE head models in EIT of brain function confers significant advantages, but image quality is critically dependent on mesh geometrical integrity. Generation of accurate models for individual subjects is time-consuming, so warping an existing idealised mesh to closely approximate specific patient geometry is being investigated. The head was modelled as an ellipsoid to obtain ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2014