Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions.

نویسندگان

  • C Djakouré-Platonoff
  • R Radermercker
  • G Reach
  • G Slama
  • J I Selam
چکیده

OBJECTIVE To evaluate in inpatient and outpatient conditions, using only non-calibration data, the accuracy of the Continuous Glucose Monitoring System (CG-MS). RESEARCH DESIGN AND METHODS Twelve, 21 and 20 type 1 diabetic patients participated in 3- day inhospital, 6-day ambulatory (i.e., 2 sensors worn consecutively) and 3-day ambulatory studies. Capillary glucose tests (7-8/day) served as comparisons. Pairs of data (excluding the 4 daily pairs used automatically by the CGMS for calibrations) were analyzed using correlation coefficient, error -grid analysis, and mean of absolute differences. RESULTS Two third and half of the sensing days were qualified as "optimal", i.e., interpretable by the CGMS program in the inpatient and outpatient studies, respectively. Correlation coefficient was 0.92, 0.81 and 0.73 in the inpatient, 6 day outpatient and 3-day outpatient studies. 98%, 93% and 96% of the data fell in the A or B error-grid "clinically acceptable" zones. Mean absolute differences between sensor and glucometer values were 25 +/- 2, 34 +/- 5 and 32 +/- 5 mg/dl. CONCLUSION CGMS may be used for assessment of glycemic trends, though accuracy is more in the range of glucometers than of laboratory tests. Inhospital utilisation improved accuracy and 6-day rather than 3-day sessions may be more appropriate to evaluate day to day reproducibility of glucose profile.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.

OBJECTIVE To evaluate the accuracy and precision of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes. RESEARCH DESIGN AND METHODS In 30 children with type 1 diabetes (mean age 11.2 +/- 4.1 years), the Navigator glucose values were compared with reference serum glucose values of blood samples obtained in an inpatient clinical research center and mea...

متن کامل

New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October...

متن کامل

A Comparative Study of Rehabilitation Information Systems in 8 Countries: A Literature Review

Introduction: This study aims to comparatively review the rehabilitation information systems in 8 countries: Canada, the United States, the United Kingdom, Sweden, Australia, Malaysia, Russia, and Iran. Methods: A comprehensive review of published studies without a time limit was explored by searching the keywords, titles, and abstracts. Studies were obtained from the Web of Science, Scopus, P...

متن کامل

PATT ERN OF RESIS TANCE TO BETA-LACTAMS IN E.COLI ISOLATED FROM URINARY TRACT INFECTIONS IN IRAN

A total of 385 urine specimens from suspected urinary tract infections were subjected to bacteriological analysis and susceptibility testing at a major university hospital laboratory in Tehran. A battery of eight beta-Iactam antibiotics, commonly prescribed in Iran, and three third-generation cephalosporins (ceftazidime, ceftriaxone and ceftizoxime) that are usually reserved for limited us...

متن کامل

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes & metabolism

دوره 29 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2003