Stability of common analytes in urine refrigerated for 24 h before automated analysis by test strips.

نویسندگان

  • P Froom
  • B Bieganiec
  • Z Ehrenrich
  • M Barak
چکیده

BACKGROUND Central outpatient laboratories might find processing large numbers of urinary samples that arrive in the late afternoon inconvenient and refrigerate them overnight before testing. Furthermore, in certain settings clinics might have difficulty assuring that the urine arrives at the laboratory during the same day as the collection. Because the stability of urine samples for delayed automated dipstick analysis (Supertron) is unknown, after defining precision, we retested urines refrigerated for 24 h to determine stability. METHODS Urinalysis was done twice on the same day and repeated after the sample was refrigerated for 24 h. Combur-10S (Roche Diagnostics) dipsticks were read automatically by a Supertron analyzer. Repeat tests on the same day were compared with tests after storage. RESULTS Leukocyte esterase had high precision, but after storage approximately 25% of the positive samples were less reactive (P: <0.005). Precision of hemoglobin retests was also high but declined significantly after storage for 24 h. Urine protein values increased after storage. The precision and stability were excellent for nitrites, glucose, and ketones. CONCLUSIONS The stability of the automated dipstick urinalysis varies with the substance tested. After refrigeration for 24 h, there is a risk of false-positive results for protein, false-negative results for leukocytes and erythrocytes, and little effect on glucose, nitrite, and ketone values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on Instrumental Precision of Refrigerated and Non-Refrigerated Auto-Analyzers in Order to Improve Quality Assurance in Biochemistry Laboratory

Background and Objective: Quality control is one of the most important components in order to improve quality assurance in laboratories during analytical steps. For this purpose, coefficient of variation plays an important role. Due to the fast improvement in technology, application of inferential statistics for the comparisons ...

متن کامل

Spectrophotometric Multicomponent Analysis of Ternary and Quaternary Drug Mixtures in Human Urine Samples by Analyzing First-order Data

      A new method was developed for the spectral resolution by further determination of three- and  four-component  mixtures  of  drugs in urine samples through  the complementary application of multivariate curve resolution-alternating least squares with correlation  constraint. In the current study, a simple method was proposed to construct a calibration set for the mixture of drugs in the p...

متن کامل

Collection and handling of 24-hour urine specimens for measurement of analytes related to renal calculi.

Analysis for calcium, magnesium, phosphorus, oxalate, uric acid, and creatinine in 24-h urine collections is often needed for the differential diagnosis of patients with renal calculi. Considerable attention has been given to improving the methods of analysis, but improper sample collection and processing can cause significant errors for calcium and oxalate in urine samples not treated with aci...

متن کامل

In vitro and in vivo interaction of oral contraceptive high dose (HD) with urine morphine diagnostic test

Introduction: Urine morphine test, in several countries is the most primarily available qualitative test for detecting opioid abusers. Since the users of illicit drugs attempt to defeat urine tests and there are also plenty of claims that usage of HD (high dose) contraceptive pills can result in false-negative results, we decided to design the present study to investigate the probable in vit...

متن کامل

Urine test strips as a source of iodine contamination.

In the course of conducting an analysis in a subset of the controlled antenatal thyroid screening study (1) samples, we recently noted that some urine samples from pregnant women in Wales, a region known to be iodine deficient, had urinary iodine concentrations in excess of 500mg=L. We suspected contamination from urine test strips. We obtained Combur Test D urine test strips (Roche Diagnostics...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 2000