Cone-beam Breast Computed Tomography: CT Density Does Not Reflect Proliferation Potential and Receptor Expression of Breast Carcinoma12
نویسندگان
چکیده
PURPOSE Recently, cone-beam breast computed tomography (CBCT) is established for the breast investigation. The purpose of the present study was to investigate possible associations between CBCT findings and histopathological features in breast cancer. METHODS Overall, 59 female patients, mean age of 64.6 years with histological proven breast cancer were included into the study. In all cases, non-contrast CBCT examination was done. The diagnosis of the identified lesions was confirmed histologically by biopsy. Immunohistochemical staining against estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2) and Ki-67 was performed for every lesion. Collected data were evaluated by means of descriptive statistics. Spearman's correlation coefficient was used to analyze the association between CT density and Ki-67 values. P values <0.05 were taken to indicate statistical significance in all instances. RESULTS The size of the lesion varied from 2.7 to 90.0, mean size, 15.88±13.0 mm. The mean value of CT density of the lesions was 63.95±38.18 HU. The density tended to be higher in tubular carcinoma. Correlation analysis identified no significant correlations between CT density and Ki-67 level (r=-0.031, P=.784). There were no statistically significant differences of CT density between tumors with different receptor status. CONCLUSIONS No significant associations between CT density and receptor status in breast cancer. Tubular carcinoma tended to have higher CT density in comparison to other subtypes of breast carcinomas.
منابع مشابه
Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کاملSimulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images
The use of mammography techniques for the screening and diagnosis of breast cancers has been limited by the overlapping of cancer symptoms with normal tissue structures. To overcome this problem, two methods have been developed and actively investigated recently: digital tomosynthesis mammography and cone beam breast CT. Comparison study with these three techniques will be helpful to understand...
متن کاملAreas of breast tissue covered in cone beam breast CT imaging
The value of cone beam breast computed tomography (CBBCT) imaging on covered areas of breast tissue, which is the relation between imaging quality and CT dose were studied. Multi-energy spectrum was used to radiate same-size built-in calcifications and lump breast motifs under the condition of the same number of particles by utilizing the Monte Carlo-based GATE simulation software; breast motif...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...