Radiofrequency coils for musculoskeletal magnetic resonance imaging.

نویسندگان

  • Kambiz A Asher
  • Neal K Bangerter
  • Ronald D Watkins
  • Garry E Gold
چکیده

Dedicated and specialized radiofrequency coils are critical for high quality musculoskeletal magnetic resonance imaging (MRI). Dedicated coils improve the signal to noise ratio, allowing for faster or higher resolution examinations. Transmit-receive coils can reduce heating at high field strength. Finally, novel radiofrequency coils can be used for assessment of tissue biochemistry, as seen with sodium MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

RADIOFREQUENCY COIL DESIGN AND APPLICATION TO MAGNETIC RESONANCE IMAGING AND CONTROL OF MICRO-BEADS by

Radio Frequency coil development, one component of a functioning magnetic resonance imaging (MRI) system, has evolved since the beginning of MRI into a very diverse area. Today for example, transmit and receive coils, volume and surface coils, and single channel and multiple channel coils are all included. Coils are created to fit the particular needs of specific research purposes, taking into ...

متن کامل

In vivo multiple-mouse MRI at 7 Tesla.

We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...

متن کامل

High Temperature Superconducting Radio Frequency Coils for Nmr Spectroscopy and Magnetic Resonance Imaging

High-temperature superconductivity has a significant opportunity to improve the performance of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) systems. The low rf losses and compact size of superconducting coils allow them to improve the signal-to-noise ratio in applications where the system noise dominates that of the sample under study. These improvements tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Topics in magnetic resonance imaging : TMRI

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2010