Convertibility Between IFPUG and COSMIC Functional Size Measurements
نویسندگان
چکیده
Since 1984 the International Function Point Users Group (IFPUG) has produced and maintained a set of standards and technical documents about a functional size measurement methods, known as IFPUG, based on Albrecht Fuction Points. On the other hand, in 1998, the Common Software Measurement International Consortium (COSMIC) proposed an improved measurement method known as Full Function Points (FFP). Both the IFPUG and the COSMIC methods both measure functional size of software, but produce different results. In this paper, we propose a model to convert functional size measures obtained with the IFPUG method to the corresponding COSMIC measures. We also present the validation of the model using 33 software projects measured with both methods. This approach may be beneficial to companies using both methods or migrating to COSMIC such that past data in IFPUG can be considered for future estimates using COSMIC and as a validation procedure.
منابع مشابه
Convertibility of Function Points to COSMIC-FFP: Identification and Analysis of Functional Outliers
COSMIC-FFP (ISO 19761) represents the second generation of functional size of the software, based on its ease of understanding and use and it is applicable to various kinds of software applications; this new method has achieved rapidly an ISO recognition as an international standard as well as market acceptance in various countries. Several organizations are therefore interested in using conver...
متن کاملMeasurement Convertibility - From Function Points to COSMIC-FFP
Several organizations are interested in using convertibility ratios between COSMICFFP (ISO 19761), the second generation of functional size of the software, and Function Points Analysis – FPA (ISO 20926). This paper presents a survey of previous convertibility studies and reports on findings from an additional data set. In summary, these studies indicate that convertibility can be simple and st...
متن کاملThe analysis of the IFPUG method sensitivity
J. Albrecht`s Function Point Analysis (FPA) is a method to determine the functional size of software products. An organization called International Function Point Users Group (IPFUG), considers the FPA as a standard in the software functional size measurement. The Albrecht ́s method is followed by IPFUG method which includes some modifications in order to improve it. A limitation of the method r...
متن کاملEarly & Quick Function Point: Sizing More with Less
The Early & Quick technique was originally proposed in 1997 for IFPUG Function Points, to size software in early stages of the development process, when functional requirements are still to be established in a detailed form and/or when a rapid measure is needed for existing software from a high-level viewpoint, within limited time. Typical lack of measurement details and requirements volatility...
متن کاملProposals for increasing benchmarking data quality of projects measured in COSMIC
With the release of the COSMIC (Common Software Measurement International Consortium) measurement method version 3.0 in September 2007, the COSMIC FSM (Functional Size Measurement) method has reached a stable and mature status. Almost 10 years after its inception, COSMIC has proved itself to be a valuable functional sising method for a broad range of different software types and domains, includ...
متن کامل