Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: A review and update

نویسندگان

  • Alberto González-García
  • Jaime González-García
  • Marcio Diniz-Freitas
  • Abel García-García
  • Pedro Bullón
چکیده

OBJECTIVES Accidental displacement of endosseous implants into the maxillary sinus is an unusual but potential complication in implantology procedures due to the special features of the posterior aspect of the maxillary bone; there is also a possibility of migration throughout the upper paranasal sinuses and adjacent structures. The aim of this paper is to review the published literature about accidental displacement and migration of dental implants into the maxillary sinus and other adjacent structures. STUDY DESIGN A review has been done based on a search in the main on-line medical databases looking for papers about migration of dental implants published in major oral surgery, periodontal, dental implant and ear-nose-throat journals, using the keywords "implant," "migration," "complication," "foreign body" and "sinus." RESULTS 24 articles showing displacement or migration to maxillary, ethmoid and sphenoid sinuses, orbit and cranial fossae, with different degrees of associated symptoms, were identified. Techniques found to solve these clinical issues include Cadwell-Luc approach, transoral endoscopy approach via canine fossae and transnasal functional endoscopy surgery. CONCLUSION Before removing the foreign body, a correct diagnosis should be done in order to evaluate the functional status of the ostiomeatal complex and the degree of affectation of paranasal sinuses and other involved structures, determining the size and the exact location of the foreign body. After a complete diagnosis, an indicated procedure for every case would be decided.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of oral and extra-oral endosseous craniofacial implants by using a mesh structure for connective tissue attachment.

Connective tissue attachment to a mesh structure incorporated on the surface of oral implants and extra-oral endosseous craniofacial implants (EOECI) was investigated. Two types of implants were prepared: TI and TI-Mesh. TI was composed of an upper and a lower component, both comprised of a titanium cylinder, which could be connected using a titanium screw. The composition of the TIMesh was sim...

متن کامل

Rehabilitation of a patient with cleft lip and palate with an extremely edentulous atrophied posterior maxilla using zygomatic implants: case report.

OBJECTIVE This case report describes the clinical and surgical management of a patient with a unilateral alveolar cleft and associated extremely atrophied totally edentulous maxilla. METHOD Two zygomatic implants and four endosseous oral implants were placed under general anesthesia in a compromised maxilla to rehabilitate a 33-year-old patient with cleft lip and palate. The two specially des...

متن کامل

The effect of total nasal obstruction on the anatomy of craniofacial structures: An animal study

Background and Aims: Nasal obstruction is a common condition among children, in which delaying treatment can stabilize its negative effects on dentoalveolar structures during adulthood. In this study we aimed to investigate the effect of total nasal obstruction on the craniofacial structures of rabbits. Materials and Methods: In this animal study, total numbers of 44 rabbits with high genetic ...

متن کامل

Lifelong craniofacial growth and the implications for osseointegrated implants.

PURPOSE The sequence of observations presented is intended to alert the dental profession to complications that may occur when teeth and implants co-exist and subtle adult craniofacial growth occurs. MATERIALS AND METHODS The authors' observations of partially edentulous implant restorations with more than 20 years of follow-up included some observed changes relative to patients' remaining te...

متن کامل

Capsular Weakness around Breast Implant: A Non-Recognized Complication

Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2012